Compatibility between RELIANCE IQ version and RELIANCE Intelligent Lighting 2A system for further power savings and
ILCMS
•
No visual flicker. PWM is used for some applications to optimize the LED performance and light fixtures show no visual
flickering.
Sustainability
•
Fully encapsulated all-in-one electronics
•
IP68 protected, anodized aluminum housing designed for harsh weather environments, all fastenings in stainless steel
•
Reinforced prism available as an option
•
Operates on 3- or 5-step ferroresonant or thyristor CCRs designed in compliance with IEC or FAA requirements
•
Easy handling and maintenance by modular design with few mechanical parts
•
Compatible with existing infrastructure
Safety
•
Built-in voltage surge and lightning protection
•
Fully dimmable lights, respecting the response curve of traditional halogen lights
•
Low protrusion, high-intensity, Style 3 inset light fixtures
•
No negative slope in front of the prisms
Power Supply
An integrated, encapsulated 6.6A electronic converter. Two-pole L-823 plug for connection to the transformer. Power factor
typically >0.9 @ 6.6A.
Refer to the user manual for the 8
‑
inch or 12
‑
inch RELIANCE inset lights and the complete power table and cable loss formula.
Maintenance and Installation
The light fixture can be installed in an 8
‑
inch or 12
‑
inch base. Gaskets are sold separately. Check what gasket and bolts to
order depending on base and installation.
Refer to the user manual for the 8
‑
inch or 12
‑
inch RELIANCE lights and to the interoperability information for installation in a
specific base.
Operating Conditions
Operating temperature
-60 °C to +55 °C / -76 °F to +131 °F
Storage temperature
-60 °C to +80 °C / -76 °F to +176 °F
Humidity
Up to 100%
3.2 Dimensions and Weight
The weight depends on version of the light fixture.
Version
Weight
RT
1
– RTN – AC – AS
5.3 kg / 11.8 lb
RC – RZ – RX – RE – RT
2
– RN – SW – RS – TC – SB
6.3 kg / 13.9 lb
Notes
1
Compatible with ICAO
2
Compatible with FAA
RELIANCE Inset Lights
Introduction
8
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE AC
Page 2: ......
Page 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Page 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Page 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Page 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......