6.0 Maintenance
This section describes different steps for maintenance of the light fixture.
Before you start, make sure you have read and understand
Find out the location of the light unit that needs maintenance. If the purpose is to replace an existing light unit with new one,
make sure that corresponding unit is available. Find the type information on the identification tag with details of name.
Spare parts are available, if required. For more information, see
and the Spare Parts List document, or
contact ADB SAFEGATE for assistance.
CAUTION
Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and
create multiple safety risks.
You need to know what base the light fixture will be installed in, in order to chose the correct gasket, bolts and nuts.
Failure to follow these cautions can result in equipment damage or aircraft FOD. For more information, see
CAUTION
When a light fixture has been removed from its base, the base must be either fitted with a cover or a spare light fixture
put in its place. It is recommended that only authorized personnel disassemble fittings with prior agreement from
ADB SAFEGATE.
6.1 Basic maintenance program
There are recommended maintenance tasks to ensure that the equipment is in correct operating condition.
Maintenance tasks
Weekly
•
Visual inspection of the light fixture.
•
Removal of dust from external surfaces of the light fixture.
Monthly
•
Check of the optical window, check for mechanical damage.
•
Check for proper fixing of the light fixture in its base.
Yearly
•
Detailed inspection of the light fixture.
•
Check of the body resistance, check for mechanical damage (for example cracks around prism windows).
•
Clean of the optical windows.
A daily function check is referred to in the document:
ICAO, Airport Services Manual Part 9, Airport Maintenance Practice and FAA AC 150/5340-26A,
Maintenance of airport visual aids facilities.
The light fixture is designed for outdoor operation, however storing the light fixture outside without using it is a risk for
damage to light fixture components. For a longer storage time (more than a week), it is recommended to store the light
fixture indoors in a dry and dust free environment and at room temperature. Proper storage ensures trouble free replacement
procedures. It is strongly recommended not to store any electrical equipment outside.
6.2 Workshop Maintenance
CAUTION
Before you start, make sure you have read and understand
UM-0210, Rev. 2.0, 2020/04/30
25
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE AC
Page 2: ......
Page 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Page 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Page 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Page 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......