Integrated System Control
Overall system configuration and control is realized via a control process with integrated web server for configuration and
maintenance.
•
Each circuit is equipped with a microprocessor-controlled Master for tracking, recording and management of state of all
Remotes in the circuit.
•
The Master communicates with all the Remotes (not light fixtures) in a circuit and polls all lamps independent from the
control system.
Overall System Specifications
Description
Remote
Master
Operating temperature
-40 °C to +65 °C
0 °C to +55 °C
Storage temperature
-55 °C to +85 °C
-40 °C to +75 °C
Operating humidity
Max. 100 %
Max. 95 % non condensing
Series circuit operating voltage
-
Max. 5000 V AC RMS
Min. / max. Power line current
1.8 up to 8.25A RMS
1.8 up to 8.25A RMS
Series circuit peak voltage
-
Max. 15 kV
Maximum switching power secondary side of
transformer
300 W (single Remote) Ch A + Ch B < 300 W
(dual)
-
Maximum circuit load (CCR power)
-
30 kVA
Power consumption
Max. 8 W at 6.6 A
Max. 15 W for power supply 115-230 V Max.
65 W on primary circuit at 6.6 A
Description
Remote
Master
Enclosure protection level
IP 68 / NEMA 6 P
IP 20
LAN connection to upper control system
-
IEEE 802.3 100 BaseT / IEEE1588 PTP
Net voltage of power supply
-
115 - 230 V AC ±15 %, 50/60 Hz
MTBF
> 200.000 h
> 200.000 h
Indicative MTTR
< 30 min
< 60 min
Lightning protection
20 kA (8/20 micro sec.)
17 kA (8/20 micro sec.)
Description
Remote
Master
EMC (CE approved)
Compliant to the EN 61000-6-4 (EMC emission standard)
Compliant to the EN 61000-6-2 and 6-5 (EMC immunity standard)
Compliant to the 60950 (IT equipment standard)
Power Up Mode
On; Off; Flashing; Maintained (last commanded state)
Fail-Safe Mode
On; Off; Flashing, Maintained (last commanded state)
Number of controlled and monitored lamps
per unit
1 or 2
Up to 300 Remotes or 600 lights, if dual
Remotes are used
Number of I/O Remotes per circuit
-
Max. 16
Transmit Frequency
11 different frequency bands between 20 kHz and 200 kHz
Data transmission rate power line
Up to 8 kbps
Up to 8 kbps
RELIANCE Intelligent Lighting Platform II
RELIANCE Intelligent Lighting Master
8
Copyright
©
ADB Safegate, All Rights Reserved