2.6 Operation
2.6.1 Circuit Specifications
Cable type L-824 is recommended, for example FLYCY or equivalent. The following parameters (
3
) represent the specific
characteristic needed in an equivalent L-824 cable. Reuse of existing installations and layout with maximum cable length or
number of lights to be verified.
Cable type (specification)
L-824
Capacity of the cable
<165 nF/km
3
Inductance of the cable
<0.20 mH/km
3
typical impedance (125 kHz)
35 Ohm
Attenuation of the signal at 125 kHz
<5.8 dB/km
3
Length of serial circuit
20 km roundtrip (12.4 miles)
maximum
Insulation resistance of the series circuit against the L-824 shield or
ground
50 Megaohms minimum
4
Secondary transformer attenuation
≤ 23 dB at 100 kHz
3
Note
Notes
3
Contact ADB SAFEGATE for support
4
Technical requirement, not excluding ICAO /FAA compliance
96A0480, Rev. B, 2019/12/06