Note
Cable lengths should not exceed 100 m.
4.3.2.3 IQ function load
The IQ function load can be divided into:
Stationary lamp load:
32 W
This load must be considered, when calculating the total CCR load.
Dynamic IQ load:
12 W
This load has to be included when calculating the secondary load of the
transformer.
Total load:
44 W
This load must be considered, only when calculating the secondary load of the
Isolation Transformer.
4.3.3 Transformer selection guidelines
Cable area
2.5 mm
2
Cable area
4 mm
2
Total load
(W)
Transformer
(W)
SafeLED IQ
<50 m
74
100
50-100 m
104
150
<50 m
64
100
50-100 m
84
100
SafeLED IQ (2A)
<50 m
47
200
50-100 m
50
200
<50 m
46
200
50-100 m
48
200
UM-0102, Rev. 2.5, 2019/05/07
11
Copyright
©
ADB Safegate, All Rights Reserved