SETTINGS: Human-Machine interface configuration
−
SCAN LOAD: to measure/scan the loads connected at the outputs of each circuit
−
MOD. MEAS.: gives the voltage and current measurements for each circuit
−
MOD. DIAG: gives the diagnosis of the outputs of each module
−
ENET PATCH: to edit the patch of the three ARTNET or sACN universes for each circuit
−
ENET INFO: general information on the ARTNET/sACN universes and the Ethernet connection
−
ENET SET.: to configure the three ARTNET/sACN universes, the IP address and the RDM.
−
SERVICE: function available to ADB technical service only
−
SYNCHRO: to synchronise the parameters recorded between each of the controllers
Note
:
All the information displayed in the different menus originates from controller 1 if two controllers
are present in the cabinet.
If only controller 2 is present, all the information displayed in the different menus will originate
from the latter. When changing the patch, power multiplication factor, law... the new data is sent
to each controller. The circuits defined as « empty slot » or « undefined slot » are not editable and
not visible in any screens. It appears again when the circuit will not be declared as
“empty slot” or
“undefined slot”.
7.1
P
ATCH
M
ENU
This function is used to configure a patch on a circuit or set of circuits for the DMX A and DMX B signal.
This configuration enables the user to attribute the value of a DMX A and DMX B signal channel to the
c
ontrol of one of the cabinet’s circuits.