EURODIM TWIN TECH
Page
70
sur
92
Thyristor (per circuit):
1 -
Displays "
OK
" if the breaker is engaged
2 -
Displays "
TRIPPED
" if the breaker has blown
Load (per circuit)
Sinewave & Thyristor with diag:
1 -
Displays "
N/A
":
•
The control is set to zero
•
and/or the output voltage is too low
2 -
Displays "
NO
":
•
If the control value is > 0
•
The output voltage is measured
•
and the current is not measured
3 -
Displays "
YES
"
•
If the control is present
•
And the output voltage and the output current is measured
Overloads
(per circuit)
Sinewave:
1 -
Displays "
light
": if the voltage is > 13 A for 30 secs
2 -
Displays "
medium
": if the current is > 16 A for 10 secs
•
Here, the control decreases every 500 ms until the current reaches < 13
A
3 -
Displays "
Severe
": if the current is > 20 A for 1 sec
•
The control is automatically set to zero
•
After 2 mins, an actual control test is repeated and if the overload is
"severe" again, a second test is conducted. If the overload is still
severe
,
a status message is displayed at the bottom of the screen, requesting the
user to set all the DMX/ARTNET inputs of the circuit to zero for 30 secs.
Thyristor with diag.:
1 -
Displays “
N/A
” if the breaker has blown
2 -
Displays "
YES
” if the breaker is
OK and:
•
If the load is > 3.5KW (for a 3kW module)
Summary of Contents for EURODIM TWIN TECH