7.13.2
sACN Information
For each of the three universes (1, 2, 3, change the information with the arrow key), the following
information is available:
−
Mode: Not used or ARNET or sACN (see "ENET SET" menu)
−
Present:
•
"Yes": detection of the Ethernet frame corresponding to the universe,
•
"No": no reception of the Ethernet frame corresponding to the universe.
−
Fail: action implemented
in the absence of the universe (see “Priority/D
MX
fail” menu), three actions
are possible:
•
"last value": the last values received to control the circuits are used permanently as long as the
universe is missing,
•
"cue" 0: the values of the universe channels are replaced by the content of cue 0 and will be
played as long as the universe is missing,
•
"black": the control value of each circuit fades to zero intensity (black) in 5 seconds.
•
When the universe is present once more, a fade is launched to the intensities given by sACN in
a time of 5 seconds.
When the universe is present once more, a fade is launched to the intensities given by sACN in a time of 5
seconds.
−
start addr.: value of the universe channel to address cabinet output 1, see "ENET PATCH" menu
•
"x"
: 1 ≤ x ≤ 512
•
"not used": channel value = 0 or > 512
•
"- - - - -": no circuit physically present in cabinet location 1, or circuit identification error in
cabinet location 1 or operating fault.
−
Patch: see "ENET PATCH" menu,
•
Yes: the addressing entered in each patch at the circuits is not in ascending order,
•
No: the addressing entered in each patch at the circuits is in ascending order, e.g. 1, 2, 3, 4,
….,
128 in the case where 32 modules are present in the cabinet.
−
Univers: Value of the univers between 0 and 63999).