EURODIM TWIN TECH
Page
89
sur
92
9
F
AULT
-C
LEARING
G
UIDE
Each controller is equipped with several LEDs for visual monitoring the information available on the
interface.
Light
State
Operation
Action
RUN light (green)
Flashes
OK
RUN light (green)
Solid or off Controller operating error (crashing)
Switch the cabinet off/on at
the mains to remove the error,
where applicable
DMX A, B (orange)
Flashes
Communication with the console
DMX A, B (orange)
Off
No communication with the console Verify the connection with the
console at the cabinet
Ethernet (orange)
Flashes
Communication ensured with the
network
Ethernet (orange)
Off
No communication with the
network
Verify the connection at the
cabinet
Alarm (red)
Solid
Alarm detected
See diagnostic screen
DMX A, B ENET,
ALARM
Flash
Controller operating error
Switch the cabinet off/on at
the mains to remove the error,
where applicable
Summary of Contents for EURODIM TWIN TECH
Page 1: ..._____________ Eurodim Twintech Dimmer Cabinet _____________ User Manual V2 0 ...
Page 2: ......
Page 94: ...EURODIM TWIN TECH Page 92 sur 92 Notes ...
Page 95: ......