Appendix B - Technical Reference
150-454-111-06
30
February 25, 2000
HRE-454
Table 5.
HRE-454 Deployment Rules for Doublers and Remote Units
Orientation
Occupied
Slots
Solar
Load
(a)
(a)
Solar Load: Full = maximum sunlight exposure per TR-TSY-000057.
Solar Load: None = indoor or fully shaded.
EDU-451,
HDU-451 List 3 & List 4
Max. Ambient Temp
HDU-451 List 1 & List 2
All HRU Units
Max. Ambient Temp
(b)
(b) All maximum ambient temperatures of 115 °F (46 °C) or more comply with the outside deployment requirements of Section 10.2.1.3
in TA-NWT-001210.
HDU-404
All list numbers
Max. Ambient Temp
Vertical
4
Full
115 °F 46 °C
100 °F 38 °C
125 °F 52 °C
Vertical
4
None
125 °F 52 °C
110 °F 43 °C
135 °F 57 °C
Vertical
3
Full
125 °F 52 °C
110 °F 43 °C
135 °F 57 °C
Vertical
3
None
135 °F 57 °C
120 °F 49 °C
145 °F 63 °C
Vertical
2
Full
135 °F 57 °C
120 °F 49 °C
145 °F 63 °C
Vertical
2
None
145 °F 63 °C
130 °F 54 °C
155 °F 68 °C
Vertical
1
Full
145 °F 63 °C
130 °F 54 °C
155 °F 68 °C
Vertical
1
None
155 °F 68 °C
140 °F 60 °C
165 °F 74 °C
Horizontal
4
Full
105 °F 40 °C
90 °F 32 °C
125 °F 52 °C
Horizontal
4
None
115 °F 46 °C
100 °F 38 °C
135 °F 57 °C
Horizontal
3
Full
115 °F 46 °C
100 °F 38 °C
135 °F 57 °C
Horizontal
3
None
125 °F 50 °C
110 °F 43 °C
145 °F 63 °C
Horizontal
2
Full
125 °F 50°C
110 °F 43 °C
145 °F 63 °C
Horizontal
2
None
135 °F 57 °C
120 °F 49 °C
155 °F 68 °C
Horizontal
1
Full
135 °F 57 °C
120 °F 49 °C
155 °F 68 °C
Horizontal
1
None
145 °F 63 °C
130 °F 56 °C
165 °F 74 °C