Replacing the Stainless Steel Dome Cover
It is necessary to replace the following items: stainless steel dome cover, metal locking clamp, and O-ring. It is
recommended that the desiccant bags be replaced when the enclosure is opened. Use Davison Chemical Corp.
Proteck-Sorb-121 or equivalent desiccant.
Replacing LPU Arrestor Boards
If any of the enclosure plugs experience severe lightning stress, ADC recommends replacing the LPU board for
that plug. To replace LPU arrestor boards, perform the following steps:
1
Clean the dome cover and clamp of dust and debris.
2
Remove the clamp and dome cover as described in
“Replacement Parts” on page 57
3
Remove the defective LPU board.
4
Insert a new LPU board in the vacant position.
5
Replace other defective LPU boards in the same manner. Note that the LPU board must be reattached so that
pin 1 of the board is connected to the edge connector pin which, in turn, is connected to the green or braided
shield ground wire. If the LPU board is attached in any other way, protection will not be provided.
6
Replace O-ring if damaged.
7
Replace the cover and clamp and repressurize the housing if required (see
“Closing the HRE-454 Enclosure”
for more information).
The cover, clamp, O-ring, and LPU surge arrestors may be replaced in the field if they become
damaged. See
for replacement kits.