Installation
150-504-100-03
10
August 1, 2002
HRE-504 List 1, List 1B, and List 2
Large Pole Mounting
Use the procedure below to mount the enclosure on a pole with a diameter greater than 7 inches (17.78 cm).
shows the mounting bracket.
Have the following equipment ready before you begin:
•
Four
3
/
8
-inch (0.952 cm) lag bolts, 4 inches (10.16 cm) long minimum
•
Four
3
/
8
-inch (0.952 cm) washers
•
One wrench
•
One pencil
•
One drill with a
1
/
4
-inch (0.635 cm) bit
To mount the enclosure, follow these steps:
1
Select a convenient mounting location on the pole.
2
Remove the enclosure base mounting bracket by removing the four bolts that connect each side plate, as
shown in
3
Position the mounting bracket with the stub down against the pole and mark the location of the top outside
holes. Use the four corner mounting holes for this application. Remove the mounting bracket.
4
Drill four
1
/
4
- inch (0.635 cm) diameter by 3-inch (7.62 cm) deep holes at the locations marked in
5
Start a lag bolt in each of the two top matched bolt mounting slots by tightening them into the pole
approximately
2
/
3
of an inch.
6
Insert the lag bolts into the two holes on the outside bottom of the mounting bracket. Tighten the lag bolts.
7
Secure the enclosure bracket to the pole by securely tightening all lag bolts.
8
Reattach the enclosure base mounting brackets with the four side plate bolts and torque the mounting bracket
bolts to 30 to 40 inch-pounds (3.4 to 4.5 Newton-meters).
9
If the cable stub connects to an underground cable, dress the cable down the pole to the splice case. If the
cable stub connects to an aerial cable, form a drip loop in the cable and dress it up the pole to the splice case.
Flat Surface Mounting
Use the procedure below to mount the enclosure on a flat surface or in a manhole. You must allow room for
enough top clearance to remove the cover. Allow at least 3 inches (7.62 cm) of clearance above the dome if the
31° tilt feature is used. Allow at least 10 inches (25.4 cm) of clearance if the tilt feature is not used.
Have the following equipment ready before you begin this procedure:
•
Four
3
/
8
-inch (0.952 cm), 16 NC anchor bolts, 2-
1
/
2
inches (6.35 cm) long for wall mounting
•
Four
3
/
8
-inch (0.952 cm) washers
•
One wrench
•
One pencil
•
One drill with a
1
/
4
-inch (0.635 cm) bit
To mount the enclosure, follow these steps:
1
Select a mounting location on a flat surface.
2
Remove the enclosure base mounting bracket by removing the four bolts that connect each side plate, as
shown in
Summary of Contents for 150-2202-01
Page 4: ...Inspecting the Shipment 150 504 100 03 iv August 1 2002 HRE 504 List 1 List 1B and List 2...
Page 8: ...List of Tables 150 504 100 03 viii Augusr 1 2002 HRE 504 List 1 List 1B and List 2...
Page 53: ...Appendix D Abbreviations 150 504 100 03 46 August 1 2002 HRE 504 List 1 List 1B and List 2...