7
Cut the cable stub screen divider approximately 6 inches from the cable stub butt.
8
Fold each corner at a 45° angle to the center of the screen. See
9
Fold the screen divider back on itself several times and tape it to prevent it from unfolding.
10
Position the folded and taped screen divider between the spliced and taped Group 1 and Group 2 pairs.
11
Seal and close the splice case according to the splice case instructions.
Figure 17.
Screen Folding Diagram
R
EPLACEMENT
P
ARTS
The HRE-504 contains LPU surge arrestors that may be replaced in the field, if needed. See the following for
instructions on replacing the LPU surge arrestors and see
for replacement part numbers.
Additionally, ADC recommends that the O-ring be closely examined whenever the housing is opened for
maintenance. If the O-ring is damaged, replace it.
To replace the stainless steel dome cover it is necessary to replace the following items: stainless steel dome cover,
metal locking clamp, and O-ring. It is recommended that the desiccant bags be replaced when the enclosure is
opened. Use Davison Chemical Corp. Proteck-Sorb-121 or equivalent desiccant.
To Replace LPU Arrestor Boards:
1
Clean the dome cover and clamp of dust and debris.
2
Remove the clamp and dome cover as described in
“Opening the Enclosure” on page 18
3
Remove the defective LPU board.
4
Insert a new LPU board in the vacant position.
5
Replace other defective LPU boards in the same manner.
If an enclosure plug receives severe lightning stress, ADC recommends replacing the LPU
board for that plug.