Installation
150-504-100-03
16
August 1, 2002
HRE-504 List 1, List 1B, and List 2
I
NSTALLING
D
OUBLER
OR
R
EPEATER
U
NITS
To install either the doubler or repeater unit, perform these steps:
1
Slide the unit into the card guides of the slot, then push the unit into the enclosure until it is seated in the slot
connector.
2
Push the unit into the card edge connector until it is entirely within the card guide. The unit should snap into
place, indicating that it is properly seated.
lists the slot pair assignments for the doubler and repeater units supported by the HRE-504.
Table 1.
Slot Pin Assignments
Signal
Side Direction
Connector Pin
Tip
1
Input
6
Ring
1
Input
5
Tip
2
Input
12
Ring
2
Input
11
Tip
1
Output
4
Ring
1
Output
3
Tip
2
Output
9
Ring
2
Output
8
Ground
--
--
1
Ground
--
--
10