150-357-200-02, Issue 2
Provisioning
HXU-357 List 1
February 9, 1999
25
Table 6.
System Configuration Status
Type
,
to select
…
DS3 INTERFACE STATUS
(See
Configuration Status”
on page 44
Operating mode = (C-bit / P-bit parity)
Line code = B8ZS
Line buildout = (0-50 ft. / 50 to 450 ft.)
Transmit timing = (local / loop)
BER threshold = (BER alarm setting)
BER value = (current BER setting)
Loopback = (none, facility, terminal, remote facility)
Service mode = (IN-SERVICE / OUT-OF-SERVICE)
Type
,
to select
…
DS1 INTERFACE STATUS
Select channel (1-28 channel number)
Channel = channel number
Line code = AMI / B8ZS
Line buildout = length in feet
Loopback = (none, facility, terminal, remote facility)
Service mode = (IN-SERVICE / OUT-OF-SERVICE)
Type
,
to select
…
SYSTEM STATUS
Protective mode = protected / unprotected
On-line card = (A/B)
Date = (MM/DD/YYYY)
Time = (HH:MM:SS)
System name = System 3190
System location = unknown location
Contact person = default name
Type
,
…
IP ADDRESSES
These addresses must
match those defined
under the HMU. See
“Appendix B - Network
Addresses” on page 56
Local IP address = 0.0.0.0
Subnet mask = 255.255.255.0
Gateway IP address = 0.0.0.0
Trap IP address #1 = 0.0.0.0 (enter IP address of HMU)
Trap IP address #2 = 0.0.0.0
Trap IP address #3 = 0.0.0.0
Trap IP address #4 = 0.0.0.0
Local C-bit IP address = 0.0.0.0 (not used)
Remote C-bit IP address = 0.0.0.0 (not used)
C-bit subnet mask = 0.0.0.0 (not used)