Provisioning
150-357-200-02, Issue 2
34
February 9, 1999
HXU-357 List 1
C
ONFIGURING THE
HXU DS1 I
NTERFACE
After an HLU is placed under HMU management and configured under the
HLU Maintenance Terminal screen, access the HXU-357 Configuration
Management menu to configure the DS1 interface.
1
Log onto the maintenance terminal connected to the HMU craft port.
2
Type
at the prompt (<), and then press
.
3
Type the password, and then press
.
4
From the Network Status screen (for multishelf configurations), type the
number of the desired shelf ID (1 through 32), and then press
.
5
From the Shelf Status menu, select
to log onto the multiplexer.
6
At the multiplexer logon prompt (ID:), type a valid password to display
the Root menu. The default password is
public
.
7
Type
to select the Configuration Management submenu.
8
Type
to select Configure DS1 Interface.
9
Type the channel number of the HLU being configured.
10
Type
to select Set the DS1 Line Code, and then
to select (B)8ZS
line code. This is the default setting: it should not require adjustment. The
HXU and HLU must be configured identically.
11
Type
+
.
12
Type
to select Line Buildout, and then
to select 0-133 ft. The
default is 0-133 feet. It should not require adjustment.
13
Type
+
to return to the Root Menu.
The DS1 interface on the 3190 chassis must be configured as
Unequipped and Out-of-Service in order to make changes and not
report alarms to the network. Unequipped and Out-of-Service are
the default states of the DS1 interface.
TAO
ENTER
ENTER
ENTER
M
1
2
1
2
CTRL
P
2
1
CTRL
R