150-357-200-02, Issue 2
Provisioning
HXU-357 List 1
February 9, 1999
35
P
LACING THE
W
IDEBAND
3190
IN
S
ERVICE
The Wideband 3190 interfaces internally to the 28 lines at the common
DSX-1 point. Once all lines have been configured, the DS1 interface should
be Equipped and In-Service.
The DS3 interface must be configured to match the line equipment used.
Once all configuration changes have been made, the DS3 interface must be
placed In-Service.
See
and
for complete information about DS1 and
DS3 interface modes.
Placing the HXU DS1 Interface in Service
1
Log onto the maintenance terminal connected to the HMU craft port.
2
Type
at the prompt (<), and then press
.
3
Type the password, and then press
. The default password is
public
.
4
From the Network Status screen, type the number of the desired shelf ID
(1 through 32), and then press
.
5
From the Shelf Status menu, select
to log onto the multiplexer.
6
At the multiplexer logon prompt (ID:), type a valid password to display
the Root menu. The default password is
public
.
7
Type
to select Configuration Management.
8
Type
to select DS1 Equip / Unequip.
9
Type the number of an individual channel line or select all channels by
typing
.
10
Do one of the following:
a
Set the state to EQUIPPED by typing
.
An Equipped DS1 or DS3 channel can be monitored and report
alarms, whether or not it is In-Service. DS1 channels that will not
be used should be configured as Unequipped.
TAO
ENTER
ENTER
ENTER
M
1
7
0
1