Provisioning
150-357-200-02, Issue 2
44
February 9, 1999
HXU-357 List 1
Multiplex Direction
•
DS1 Transmit Loss of Signal alarm (Channels 1 through 28 are never
masked.)
•
DS1 Transmit Fail alarm (channels 1 through 28)
V
IEWING
S
YSTEM
C
ONFIGURATION
S
TATUS
The Wideband 3190 provides a common interface with an open architecture.
This open architecture allows any industry-compliant 3190 card to access a
managed DS3-based shelf, thus affording greater flexibility than many other
systems. The flexibility the Wideband 3190 affords is due in part to the
separate multiplexing and management functions which must be
independently configured.
Before placing the system in service, take a moment to reassess your
configuration requirements.
•
Check shelf status by accessing the HMU TAO software and viewing the
Shelf Status screen.
•
Check the HLU Maintenance terminals screens that are accessible
through the Shelf Status menu.
•
Check the System Configuration Status screens that are accessible when
logging onto the multiplexer Root Menu through the Shelf Status Screen.
To access the System Configuration Status:
1
Log onto the maintenance terminal connected to the HMU craft port, if
you are not already logged on.
2
Type
at the prompt (<), and then press
.
3
Type the password and then press
. The default password is
public
.
Before placing the Wideband 3190 in service, verify that all
necessary provisioning changes have been made.
TAO
ENTER
ENTER