Provisioning
150-357-200-02, Issue 2
46
February 9, 1999
HXU-357 List 1
3
Access the Root Menu from the Shelf Status Menu by typing
, and then
the password.
4
Type
to select Performance Management.
5
Select one of the following performance histories or clear the statistics
by typing the corresponding number:
•
DS3 Performance Current 15 Minutes
•
DS3 Performance Last 24 Hours
•
DS1 Performance Current 15 Minutes
•
DS1 performance Last 24 hours
•
Clear PM Stats
6
Type
+
to return to the Root Menu.
U
PGRADING THE
M
ULTIPLEXER
S
OFTWARE
Uploading a new version of multiplexer software assumes the following
conditions:
•
a serial connection between the maintenance terminal and the HMU
•
a 10BASE-T Ethernet connection between the multiplexer and the HMU
•
the AUX port is set up to communicate with the multiplexer
•
a communications package on the maintenance terminal, such as
HyperTerminal or ProComm, using XMODEM
When performing a software download in a protected system,
the software must be loaded to both multiplexer modules
individually. Upon completion of a download, the system
switches to the standby module, at which time a second
download must be initiated to complete a full system
upgrade.
M
2
1
2
3
4
5
CTRL
R