150-357-200-02, Issue 2
Provisioning
HXU-357 List 1
February 9, 1999
49
2
Select
, Start New Program, and then select
to start the downloaded
program. This causes an HXU reset and a protection switch to the
standby HXU. The standby HXU now becomes the active HXU.
3
Repeat the entire download procedure for the other HXU.
R
ESTORING
F
ACTORY
D
EFAULTS
shows the HXU-357 default software settings. For
maintenance purposes, the HXU-357 can be restored to its factory default
settings:
1
Log onto the maintenance terminal connected to the HMU craft port.
2
Type
at the prompt (<), and then press
. The default
password is
public
.
3
Type the password, and then press
.
4
From the Network Status screen (for multishelf configurations), type the
number of the desired shelf ID (1 through 32), and then press
.
5
From the Shelf Status menu, select
to log onto the multiplexer.
6
At the multiplexer logon prompt (ID:), type a valid password to display
the Root menu. The default password is
public
.
7
Type
for System Administration.
8
Type
to reset the nonvolatile RAM.
9
Type
to reset to the factory defaults.
10
Press
+
to return to the Root Menu.
Although HXU-357 factory defaults can be restored using the
following procedure, ADC does not recommend it for systems
that are fully configured and operational. This procedure will
disrupt IP-based functions and may result in the loss of
customer service.
4
1
TAO
ENTER
ENTER
ENTER
M
5
4
1
CTRL
R