150-357-200-02, Issue 2
Provisioning
HXU-357 List 1
February 9, 1999
33
C
ONFIGURING THE
HXU DS3 I
NTERFACE
Configure the DS3 interface according to network requirements.
1
Log onto the maintenance terminal connected to the HMU craft port.
2
Type
at the prompt (<), and then press
.
3
Type the password, and then press
. The default password is
public
.
4
From the Network Status screen (for multishelf configurations), type the
number of the desired shelf ID (1 through 32), and then press
.
5
From the Shelf Status menu, select
to log onto the multiplexer.
6
At the multiplexer logon prompt (ID:), type a valid password to display
the Root menu. The default password is
public
.
7
Type
to select the Configuration Management from the Root Menu.
8
Type
to select Configure DS3 Interface.
9
Configure the DS3 interface according to CO requirements. Type the
number of the parameter and then select an appropriate setting. See
for a listing of available settings. Default settings are
marked with an asterisk.
Configure DS3 mode
Configure DS3 line buildout
Configure DS3 transmit timing
Configure DS3 BER threshold
10
Press
+
to return to the Root Menu.
The DS3 interface on the 3190 chassis must be configured as
Out-of-Service in order to make changes and not report
alarms to the network.
TAO
ENTER
ENTER
ENTER
M
1
1
1
2
3
4
CTRL
R