Provisioning
150-357-200-02, Issue 2
50
February 9, 1999
HXU-357 List 1
Table 11.
HXU-357 Default Software Settings
NAME/ITEM
DESCRIPTION
DEFAULT
DS3 Operating Mode
Normal operating mode is
M13
M13 parity mode
DS3 Line Buildout
Selectable DS3 cable length
0-100 feet
DS3 Transmit Timing
Selectable local (internal
clock) or looped timing
(external data)
Local (internal)
DS3 Service Mode
In-Service: normal operation
Out-of-Service:
configuration, maintenance
to perform loopbacks
Out-of-Service
DS3 Facility Loopback
DS3 loopback toward the
span
Disabled
DS3 Terminal Loopback
DS3 loopback toward the
equipment
Disabled
DS3 Remote Facility
Loopback
DS3 loopback toward the
span
Disabled
DS1 Line Coding
Selectable to AMI or B8ZS
BSZS
DS1 Line Buildout
Selectable cable length to
DSX cross-connect
0-133 ft.
DS1 Service Mode
In-Service: normal operation
Out-of-Service:
configuration, maintenance
to perform loopbacks
Out-of-Service
DS1 Equipped or
Unequipped State
Equipped: reports alarms
Unequipped: no alarm
reporting
Unequipped
DS1 Facility Loopback
Loopback toward the
equipment
Disabled
DS1 Terminal Loopback
DS1 loopback toward the
span
Disabled
DS1 Remote Terminal
Loopback
DS1 loopback toward the
span
Disabled
Password
Up to 30 alpha-numeric
characters long
public
(not case-sensitive)