54
American Dryer Corp.
113329 - 14
SECTION IX
REVERSING TIMER SPIN / DWELL ADJUSTMENTS
Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is
located in the upper rear area of the dryer.
Both the dwell (stop) time and tumbler spin time are adjustable by mode selection switches located on the electronic
timer (as noted in the illustration below).
TIMING LEGEND
SPIN TIME
Adjustment Position Number
Counterclockwise - Clockwise
Time in Seconds
*
30 - 150
DWELL (STOP) TIME
Adjustment Position Number
Counterclockwise - Clockwise
Time in Seconds
*
5 - 10
* Values shown are +/- 1-second.