Configuring with an ASCII Terminal
5-24
Campus-REX RS Interface Card User Manual
U
PDATING
THE
C
AMPUS
-REX F
IRMWARE
Before you can upgrade a Campus-RS unit, you must first download the
firmware file(s) to your computer. These files are available on the ADC Web
site, www.adc.com.
1
From the Main Menu, type
then press
. The Diagnostics menu
displays.
2
Type
and press
to select Download Mode.
3
Type
and press
to confirm the selection.
The console freezes and the Test LED on the line unit or desktop unit
front panel illuminates, indicating that the Campus-RS unit is in
Download Mode.
4
Close the terminal emulation program you are using for the ASCII
terminal.
5
Start the Download Utility (DNL32.exe).
4
ENTER
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:29:35
Local Unit ID:
Campus-REX Unit #34
Local I/F:
REX
Remote Unit ID: Campus-REX Unit #12
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DIAGNOSTICS MENU
1)
LOOPBACK SETTINGS MENU
2)
DOWNLOAD MODE
(R)eturn
ENTER CHOICE>
2
ENTER
Y
ENTER