Configuring with an ASCII Terminal
Campus-REX RS Interface Card User Manual
5-15
C
ONFIGURING
A
LARMS
You can configure four different alarm options:
•
HDSL ES Alarm Threshold determines the number of errored seconds
that must occur to trigger an alarm
•
HDSL Margin Alarm Threshold determines the margin, in dB, that
triggers an alarm
•
Alarm on Local I/F LOS lets you enable or disable the local Loss of
Signal alarm
•
Alarm on Remote I/F LOS lets you enable or disable the remote Loss of
Signal alarm
To configure the alarm options:
1
From the Main Menu, type
then press
. The System Settings
Menu displays.
2
Type
then press
. The System Parameters menu displays.
3
ENTER
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:41
Local Unit ID:
Campus-REX Unit #34
Local I/F:
REX
Remote Unit ID: Campus-REX Unit #12
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM SETTINGS MENU
1)
SYSTEM PARAMETERS
2)
HDSL PARAMETERS
(R)eturn
ENTER CHOICE>
1
ENTER
CAD1069i5.book Page 15 Thursday, May 30, 2002 7:32 AM