background image

8

/

0

7

 

 

1

0

5

1

8

7

A

E

 

 

C

le

ar

G

ai

n

®

 T

o

w

er

-M

o

u

n

te

d

 A

m

p

lif

ie

rs 

2

w w w . a d c . c o m  

•  

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  

•  

1 - 8 0 0 - 3 6 6 - 3 8 9 1

ClearGain

®

 Tower-Mounted Amplifiers 

Americas

Introduction

Unacceptable network quality is one of the main 
reasons for mobile subscriber churn. With industry 
churn at their current rates, a service provider’s 
entire customer base could be lost in as few as 
three years. The cost of acquiring new subscribers 
to replace the existing customer base can be 
enormous. Improvements in quality of service can 
directly impact a service provider’s profitability 
through the cost savings associated with 
increased subscriber retention and the additional 
revenue gained from increased billable minutes  
of use resulting from improved signal quality.

While subscribers are willing to pay a premium 
for data services, improved quality of service is 
necessary to provide new data services. Due to 
the tradeoff between bit rate and bandwidth 
inherent to data services, improved signal 
quality is required to achieve the same level of 
performance at even higher data rates. ADC’s 
ClearGain Tower-Mounted Amplifiers help provide 
this improvement in signal quality. 

TMAs improve signal quality by boosting the 
uplink (RX) signal of a mobile system immediately 
after the antenna. This compensates for the loss 
in signal strength that occurs when the signal 
is passed through the coaxial feeder cable to 
the base transceiver station (BTS) at the base 
of the tower. ClearGain TMAs perform this 
amplification with the lowest possible noise 
contribution, resulting in a substantial increase 
in receiver performance and an improvement in 
overall coverage. These improvements in quality 
of service allow mobile 
subscribers to place more 
calls, make longer calls, 
and successfully complete 
calls in an expanded 
geographic area, resulting 
in increased revenue.

System Overview

The ClearGain TMA system is modular, consisting 
of a Masthead Unit (MHU), a Power Distribution 
Unit (PDU) and a Bias-T Unit. This system provides 
full compatibility with all base stations. The 
ClearGain MHU offers dual duplex operation and 
incorporates a highly advanced fixed-gain, low-
noise amplifier (LNA) and high-performance filters 
for added reliability. The MHU amplifies each band 
to maximize signal quality and optimize coverage.

The ClearGain MHU features a slim, lightweight 
design. This allows two ClearGain TMAs to 
be mounted with one set of brackets thereby, 
conserving valuable and costly tower space 
and reducing clutter on the tower. The TMA 
is protected with a strong, aluminum sleeve 
construction designed to ensure superior weather 
protection and resistance to corrosion, resulting in 
increased reliability.

In the ClearGain TMA system, DC power is 
supplied to the MHU from a ClearGain PDU. The 
PDU also provides alarming and monitoring of the 
feeder cable and up to six MHUs from a single 
unit. The flexible design of the ClearGain PDU 
allows it to be rack- or wall-mounted on the side 
of a BTS cabinet.

An external Bias-T Unit is used in conjunction 
with the ClearGain PDU. The Bias-T inserts DC 
power onto the coaxial cable and extracts alarm 
and monitoring signals from the coaxial cable.

+   -

INpUt

NO cOM Nc

ALARM

MhU

DIScONNect

power Distribution Unit

MhU1

MhU2

MhU3

MhU4

MhU5

MhU6

Base

Station

clearGain™

tMA

ANt

BtS

Bias-t

BtS

 

Antenna

BtS

Summary of Contents for CG-1900/800-DB-FB-DIN

Page 1: ...crease receiver performance and improve overall coverage Features Provides amplification of the Band Highly advanced LNA amplifies RX signal for improved receiver performance and increase in coverage Dual duplex feature reduces the number of feeder cable runs by providing simultaneous operation of TX and RX with low TX loss Full Band feature provides amplification of the entire band Advanced filte...

Page 2: ...ng in a substantial increase in receiver performance and an improvement in overall coverage These improvements in quality of service allow mobile subscribers to place more calls make longer calls and successfully complete calls in an expanded geographic area resulting in increased revenue System Overview The ClearGain TMA system is modular consisting of a Masthead Unit MHU a Power Distribution Uni...

Page 3: ...Loss of TX Path TX to Antenna 0 4 dB Passband Return Loss TX Band 18 dB RX Band 18 dB Intermodulation 120 dBm Maximum Input Power RMS Power 500 W Tx Rejection in Rx Band 40 dB POWER Operational Voltage 7 to 15 Vdc Operational Current 140 10 mA PHYSICAL Dimensions HxWxD 332 mm x 250 mm x 84 mm Weight 6 3 kg 13 9 lbs Color Silver Housing Aluminum CONNECTORS Antenna Connector 7 16 DIN female BTS Conn...

Page 4: ... Antenna 0 4 dB Passband Return Loss TX Band 18 dB RX Band 18 dB Intermodulation 120 dBm Maximum Input Power RMS Power 500 W Tx Rejection in Rx Band 40 dB POWER Operational Voltage 7 to 20 Vdc Operational Current 140 10 mA Alarm Current Level 350 10 mA PHYSICAL Dimensions HxWxD 332 mm x 250 mm x 84 mm 13 in x 9 8 in x 3 3 in Weight 6 3 kg 13 9 lb Color Silver Housing Aluminum CONNECTORS Antenna Co...

Page 5: ...s of TX Path TX to Antenna 4 dB Passband Return Loss TX Band 18 dB RX Band 18 dB Intermodulation 120 dBm Maximum Input Power RMS Power 250 W Tx Filter Rejection in Rx Band 40 dB POWER Operational Voltage 7 to 15 Vdc Operational Current 140 10 mA Alarm Current Level 350 20 mA PHYSICAL Dimensions HxWxD 297 mm x 287 mm x 70 mm Weight 5 5 kg 12 1 lbs Color Silver Housing Aluminum CONNECTORS Antenna Co...

Page 6: ...94 MHz 80 dB Max Input Power 10 dBm Passband Return Loss TX Band 18 dB RX Band 18 dB Intermodulation 120 dBm Maximum Input Power RMS Power 250 W Tx Filter Rejection in Rx Band 40 dB POWER Operational Voltage 7 to 20 Vdc Operational Current 140 10 mA Alarm Current Level 350 20 mA PHYSICAL Dimensions HxWxD 297 mm x 287 mm x 70 mm Weight 5 5 kg 12 1 lbs Color Silver Housing Aluminum CONNECTORS Antenn...

Page 7: ...dB Isolation in TX Path 80 dB Insertion Loss of TX Path TX to Antenna 4 dB Passband Return Loss TX Band 18 dB RX Band 18 dB Intemodulation 120 dBm Max Input Power RMS Power 800 500 W 1900 250 W Tx Filter Rejection in RX Path 40 dB POWER Operational Voltage 7 to 20 Vdc Operational Current 280 10 mA Alarm Current Level 350 520 mA PHYSICAL Dimensions HxWxD 357 mm x 287 mm x 149 mm Weight 10 5 kg 22 5...

Page 8: ...ATION Main path connectors Refer to ordering information for configurations DC injection Sample port connector TNC jack female Mounting and grounding M8 brk MH bulkhead mounting M screw brk bracket TECHNICAL DATA Impedance 50 ohms Frequency range 800 to 2200 MHz Return loss 19 dB Insertion loss 0 2 dB RF CW power 500 W PIM 3rd order 108 dBm Surge current handling capability 3kA single Operating te...

Page 9: ...m functions for the ClearGain TMA system The ClearGain Singlemode PDU provides power for up to six single frequency TMAs For dual band systems the ClearGain Dual Mode PDU provides power for up to six dual band TMAs or twelve multi frequency systems that amplify a single frequency The PDU monitors the current of the MHU If an MHU fails the ClearGain PDU gives an alarm indication The ClearGain PDU a...

Page 10: ...lemode PDU Green OK NOK LEDs Red General Alarm LED Dual Mode PDU Green Yellow OK NOK LEDs Red General Alarm LEDs Alarm output Alarm output is isolated 3 pin relay connection Normally open and normally closed connection available ENVIRONMENT Storage ETS3019 1 1 Transport ETS3019 1 2 Operation ETS3019 1 3 Housing IP40 Temperature Range Indoor Use 20ºC to 65ºC 4ºF to 149ºF Lightning Protection IEC 10...

Page 11: ...DIN Bias T Kits 7 16 DIN male to BTS 7 16 DIN female to ANT STRB DM DF G KIT 7 16 DIN female to BTS 7 16 DIN male to ANT STRB DF DM G KIT N male to BTS N female to ANT STRB NM NF G KIT N female to BTS N male to ANT STRB NF NM G KIT Power Distribution Units Single Mode PDU includes power cable and grounding cable CG PDU SMPWR Dual Mode PDU includes power cable and grounding cable CG PDU DMPWR O r d...

Page 12: ...A DIN Connectors 4 CG 1900W800 FULL DIN DD1900 with 800 Bypass Full Band TMA DIN Connectors 5 CG1900DDBFBDTBP DD1900 with 800 Bypass Full Band TMA with DC Block DIN Connectors 6 CG 1900 800 DB FB DIN Dual Band Full Band TMA DIN Connectors The TMAs include Mounting hardware Grounding cable strap length 1 5 meters Ordering information Order two per sector You have four Bias T options based on connec...

Reviews: