background image

ADCP-50-404 • Issue 2 • November 1998

Page 5

© 1998, ADC Telecommunications, Inc.

5. OUTPUT CABLE ASSIGNMENTS

Output from the DMPS-l0CE Power Supply is delivered via a 6 foot, 16 gauge cable,
terminated in a 9-pin connector. Pin assignments on the connector are as follows:

Pin 1  —  +5 Volts Pin 6  —  Earth Ground

Pin 2  —  +5 Volts Pin 7  —  Common Ground for +5 and ± 12 V

Pin 3  —  +12 Volts Pin 8  —  Common Ground for +5 and ± 12 V

Pin 4  —  No Connection Pin 9  —  –12 Volts

Pin 5  —  No Connection

See 

Figure 3

 for sketch of the 9-pin connector.

4

4555-A  

6

3 9

1 7

2

8

Figure 3. 9-Pin Connector

6. INSTALLATION

6.1  DMPS-10CE Power Supply Installation

Remove each item from its shipping container and inspect the units for signs of damage. If
there are any damaged or missing parts, immediately file a claim with the commercial
common carrier or its agent, and notify ADC Telecommunications, Inc.

Normally, the ADC DMPS-10CE Power Supply is shipped with the standard single power
unit installed. Additional DMPS-10EXP/CE expansion modules are shipped in separate
containers. Occasionally, a power supply may be shipped with expansion modules installed. In
either case, installation of the power supply involves positioning the unit in the desired rack
space, near an ac utility outlet, and securing it with the mounting hardware normally used on
the mounting rack.

Note: The DMPS-10CE Power Supply requires air for convection cooling. Air holes in
the top cover and bottom cover allow air to flow through the power supply chassis. For
this reason, be sure to mount the DMPS-10CE Power Supply in such a fashion as to
leave at least half of the top and bottom surfaces open to air movement.

Summary of Contents for DMPS-10CE

Page 1: ... throughout this manual to warn of possible hazards to persons or equipment An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided The admonishments in the form of Dangers Warnings and Cautions must be followed at all times These warnings are flagged by use of the triangular safety icon seen below and are listed in descending order of severity o...

Page 2: ...the ADC Telecommunications PatchSwitch system but will work well with other applications It will operate with any input voltage between 190 and 240 volts ac and any frequency between 48 and 62 Hz Manual adjustments are not necessary Only one ac input is necessary per shelf for up to four dc power sources the basic unit plus three expansion modules Input ac power is supplied via a six foot three co...

Page 3: ...helf requires a single ac power source 190 to 240 Vac 48 to 62 Hz to deliver up to 4 dc outputs via 9 pin cable connectors each output supplying 5 Vdc 12 Vdc and 12 Vdc Any input voltage between 190 and 240 volts ac can be accommodated without adjustment to the power supply Outputs available from each of the modules basic plus expansion modules are 5 Vdc at up to 4 5 Amps 12 Vdc at up to 1 0 Amp a...

Page 4: ...ximum 4 Modules Frequency 48 to 62 Hz Fusing On rear of basic unit 220 Vac 4 Amp Dual Time Delay Output Each Module Voltage 5 Vdc 5 12 Vdc 10 12 Vdc 10 Current 4 5 Amp DC Max 5 V 1 0 Amp DC Max 12 V 0 5 Amp DC Max 12 V Physical Chassis 3 5 19 11 inches 8 9 48 3 27 94 cm Expansion Module 3 5 3 9 9 22 inches 8 9 9 91 23 5 cm Environmental Operating Temperature 0 to 50 C 32 to 122 F Storage Temperatu...

Page 5: ...ed or missing parts immediately file a claim with the commercial common carrier or its agent and notify ADC Telecommunications Inc Normally the ADC DMPS 10CE Power Supply is shipped with the standard single power unit installed Additional DMPS 10EXP CE expansion modules are shipped in separate containers Occasionally a power supply may be shipped with expansion modules installed In either case ins...

Page 6: ...switch at the front of the power supply to off down position and unplug the power cord of the supply from its ac utility outlet b Remove and dispose of one of the four by four inch metal covers on the back of the power supply by taking off the two screws holding it in place Save the screws for use in step e below c Notice the crimped sheet metal slots to the left hand side on the base of the power...

Page 7: ...the other end of the power cord Replace the plug with a plug that matches your utility outlet d Connect the other end of the power cord to the utility outlet e Set the ac switch at the front of the DMPS 10CE Power Supply to the on I position f Verify that power LED is lit on the front of the power supply for the basic power supply and any expansion modules installed 9 REPLACING THE LINE FUSE The l...

Page 8: ...e Quotation Proposals Extension 3000 Ordering and Delivery General Product Information Systems Integration Complete Solutions from Concept to Installation Extension 3000 Network Design and Integration Testing System Turn Up and Testing Network Monitoring Upstream or Downstream Power Monitoring and Remote Surveillance Service Maintenance Agreements Systems Operation BBG Technical Assistance Center ...

Page 9: ...ial consequential or other similar damages This disclaimer of liability applies to all products publications and services during and after the warranty period This publication may be verified at any time by contacting ADC s Technical Assistance Center at 1 800 366 3891 extension 3223 in U S A or Canada or 612 946 3223 outside U S A and Canada or by writing to ADC Telecommunications Inc Attn Techni...