SCP-FRE765-041-03H
Specifications
FRE-765 List 4A
January 6, 2003
3
S
PECIFICATIONS
F
UNCTIONAL
D
ESCRIPTION
Operational Capabilities
The FRE-765 List 4A RT enclosure requires the following plug-in units:
•
one RT Line Unit which is line powered via the HDSL pairs that connect the RT to the PG-Flex COT line
units installed in a COT Shelf.
•
one Channel Unit, minimum, with a maximum installation of three Channel Units, supporting up to 24
channels.
Table 1, “FRE-765 Circuit Assignments,” on page 4
shows how circuit assignments are configured in the
FRE-765 with the following deployment rules:
–
For channel units providing four (4) circuits, Ckt 1 through Ckt 4 are used for Tip and Ring terminations.
–
For channel units providing eight (8) circuits, Ckt 1 through Ckt 8 are used for Tip and Ring terminations.
–
For a 24-channel system, you can provision a maximum of 24 POTS circuits or 8 ISDN circuits.
Each PG-Flex channel unit provides four (4) or eight (8) circuits.
Table 2, “Channel Unit Circuit Utilization,” on
shows how the channels are assigned, dependent on the type of service provided, such as:
–
Plain Old Telephone Service (POTS)
–
Integrated Services Digital Network (ISDN)
Environmental
Operating Temperature
-40 °F to +150 °F (-40 °C to +65 °C)
Operating Humidity
5% to 95% (non-condensing)
Operating Elevation
-200 feet to 13,000 feet (-60 m to 4,000 m)
Dimensions
Weight:
26.3 lb. (11.9 kg.)
Height:
19.25 in. (48.9 cm.)
Width:
14.25 in. (36.2 cm.)
Depth:
5.93 in. (15.1 cm.)
Summary of Contents for FRE-765