LTPH-TP-1044-01, Issue 1
Performance Monitoring
HXU-358 V1.04
April 6, 2001
33
Select Active Alarms from the Monitor Menu. The screen reports any active
alarms.
Figure 20.
Monitor Menu: Active Alarms
ESCP-P
Errored Seconds CP-bit Parity: Count of seconds containing
one ore more CP-bit parity errors or one or more SEF or AIS
defects.
SESCP-P
Severely Errored Second CP-bit Parity: Count of seconds
containing more than 44 CP-bit parity errors or one or more
SEF or AIS defects.
UASCP-P
Unavailable Seconds CP-bit Parity: Count of 1-second
intervals during which the DS3 path is unavailable.
Table 5.
T1/E1 and DS3 Error Definitions (Cont.)
Error Type
Description
Main
Monitor
History Config Test Inventory Quit Help
+-------- Active Alarms ---------------------------------------------------+
Alarm Description Sev Cnt First Occurrence Last Occurrence
DS3 RCV FAIL CRIT 1 03/30/01 12:46:47 03/30/01 12:46:47
STANDBY MUX FAILURE MIN 2 03/30/01 12:34:37 03/30/01 12:46:33
DS3 FACILITY LPBK MIN 1 03/30/01 12:46:33 03/30/01 12:46:33
(N)ext Page (P)rev Page (T)op Page
+------------------------------- Page 1 of 1 ----------------------------------+
ID: Test card | Card 'A' 03/30/01 12:48:02 ALARMS: CRIT