LTPH-SM-1052-04
Installing
Multiplexers
HMS-358 List 5 and List 6
July 14, 2002
49
HXU
-35
9
Configuring the STS-1 Transport Through the Config Menu
Figure 33.
Setting Up the STS-1 Transport Through the HXU-359
Step
Procedure
Installer Check
ü
1
From the Config
submenu, choose Transport, and then press
.
For more information on navigating through the menu system, refer to the procedures detailed in
“Setting Up Basic System Parameters Through the Config Menu” on page 43
H
2
Set Primary State to OOS-A using the
,
and then press
.
H
Do not configure the transport as OOS-M or OOS-A when it is selected as a clock
synchronization source.
3
Select Transport
and then press
.
H
4
Type the Tx Path Trace transmit path trace string. The string cannot be longer than 40 characters.
H
5
Set the Data Communications Channel (DCC) to ON.
H
6
Set Loopback to
NONE and then press
.
H
7
Set Line Buildout option to either >250 ft. or <250 ft. and then press
.
H
8
Set Primary State to IS and press
.
H
Continued
Main Monitor History
Config
Test Inventory Quit Help
+-------------------------Transport Configuration-----------------------+
|
|
|
+---------------------------------------------------------+
|
|
|
Primary State
:
IS
|
|
|
|
|
|
|
|
RX Path Trace
:
abcdefghijklmnopqrstuvwxyz
|
|
|
|
|
|
|
|
TX Path Trace
:
abcdefghijklmnopqrstuvwxyz
|
|
|
|
|
|
|
|
DCC
:
ON
|
|
|
|
|
|
|
|
Loopback
:
NONE
|
|
|
|
|
|
|
|
Line Buildout
:
<250 ft.
|
|
|
+---------------------------------------------------------+
|
|
|
|
(TAB) next field (Spacebar) next value (ENTER) activate (ESC) quit
|
|
|
+-----------------------------------------------------------------------+
ID: | Card 'A' 10/01/01 10:42:47 ALARMS: NONE
ENTER
SPACEBAR
ENTER
ENTER
ENTER
ENTER
ENTER