LTPH-SM-1052-04
Installing
Multiplexers
HMS-358 List 5 and List 6
July 14, 2002
59
HXU-
35
8/HXU-3
6
0
Enabling Alarms for Systems Using an HXU-358 or HXU-360 Multiplexer
Step
Procedure
Installer Check
ü
1
From the Shelf Options screen, press
to select Alarm Management. The following prompt
appears:
Which Line Unit do you want to change the alarm settings
on (1-28). (E)nable All, (D)isable All
H
2
Type the slot number of the line unit you want to enable. When you type a slot number (x), one of
the following prompts appears.
Do you want to ENABLE alarm settings for Line Unit x (Y/N)
Do you want to DISABLE alarm settings for Line Unit x
(Y/N)
H
3
Press an appropriate
or
response for the alarm setting you are changing.
H
4
If you plan to install a test card, proceed to
“Installing a Test Card (HTC) (Optional)” on page 62
.
If you plan to install a cut-through card, proceed to
“Installing a Cut-Through Card (HCC) (Optional)”
The Wideband 3190 should now be operational. If you experience any difficulties at this time, refer
to
“Installing a Test Card (HTC) (Optional)” on page 62
H
Installer Signature
?
Date
A
Y
N