SCP-PLL735-010-03H
PLL-735 Lists 1, 2 and 3
January 6, 2003
5
•
LOSW - If the alarm is on the DICOLU, then the DICOLU cannot synchronize with the A or B RT, then the
DICOLU and the A or B RT are out of service. If the alarm is on the RTs, then the A or B RTs cannot
synchronize with the DICOLU, and the DICOLU and the A or B RT are out of service
•
MISMATCH
n
- Incompatible RT
n
unit has been installed.
•
PARITYERR - The DICOLU implements parity generation and detection on the data transferred between the
PMX and the COLUs on the backplane. If parity errors are detected coming from a PMX, an alarm is
generated and all circuits are placed in a Trunk-Conditioned state.
•
BKUPMEMP - EEPROM Failure
•
NORTSW
n
- RT
n
has no application software and is awaiting software download.
Alarm Types
Any alarm may be set the alarm to any of these values:
•
Major - MJ
•
Minor - MN
•
Critical - CR
•
Not Alarmed - NA
•
Not Reported - NR
History
Current cumulative counts of the past 24 hours and historical data in the form of a 24-hour history (in 15-minute
increments) and a 7-day history (in 24-hour increments) are available to assist you in identifying problem sources.
You can view the HDSL history from the
“HDSL-A and HDSL-B History Screens” described on page 33
.
•
HDSL Interface: 24-Hour (15-minute intervals) and 7-Day (24-hour intervals) for ES and Unavailable
Seconds (UAS)
•
Alarm: Time stamp of first and last occurrence, number of occurrences for all enabled alarms