SCP-PLL735-010-03H
PLL-735 Lists 1, 2 and 3
January 6, 2003
43
ISDN-A and ISDN-B Alarm Thresholds Screens
These screens provide a means to provision the threshold crossing values for the hourly and daily ES and UAS
counts for the ISDN-A RTs.
Table 14, “ISDN-A/B Alarm Threshold Fields,” on page 44
, lists the fields of the
ISDN Alarm Thresholds and the default factory values. View the results of these settings at the
HDSL-B Status Screens” on page 22
. The ISDN-B screen displays the data for the ISDN-B connection in this
same format.
1
Select the
ISDN-A Alarm Thrshlds
option and press
to view the screen:
Figure 35.
ISDN-A Alarm Thresholds Screen
2
With the desired field selected, press the
to toggle to the correct value for that field.
3
Press a directional key to move up or down the current column, or press
to move to the next column.
Continue until you have made all desired changes.
4
Move to the
Accept ISDN-A Alarm Thresholds Changes
button, press
to accept the changes.
5
Press
to return to the DICOLU main screen, or
+ to return to the PAU/PMU main menu.
PLL-735 List 1 does not support ISDN services.
ENTER
SPACEBAR
TAB
ENTER
ESC
CTRL
R