SCP-PLL735-010-03H
PLL-735 Lists 1, 2 and 3
January 6, 2003
21
Overall Status Screen
This screen details the performance condition of the DICOLU and RT.
Table 6, “Overall Status,” on page 21
defines the conditions that appear in the HDSL, Performance and Alarms Status fields.
1
Select the
Overall Status
option and press
to view the screen:
Figure 16.
Overall Status Screen
2
Press
to return to the DICOLU main screen, or
+ to return to the PAU/PMU main menu. Refer
to the Performance and Alarms submenu screens for a detailed description of data displayed in these areas.
Table 6.
Overall Status
State
Description
HDSL Status
HDSL Link Down
HDSL link is down and System is not in Metallic Fallback.
Start up
System in start up mode where the HDSL link is acquiring synchronization.
Normal
System running normal where the HDSL link is synchronized and speech and signaling data are
flowing between the DICOLU and the RTs.
Performance
HDSL - A Margin (dB)
Summary of the A Margin in dB values.
HDSL - A ES (24 Hr.)
Summary of Errored Seconds occurring on A.
HDSL - B Margin (dB)
Summary of the B Margin in dB values.
HDSL - B ES (24 Hr.)
Summary of Errored Seconds occurring on B.
Alarms
System
Summary of types of Active alarms.
HDSL - A
Summary of types of Active alarms.
HDSL - B
Summary of types of Active alarms.
ENTER
Status indicators for
the POTS interfaces
the HDSL span and
HDSL performance
summary in terms of
margin and ES count
Status of current
HDSL and
System alarms
ESC
CTRL
R