SCP-PLL735-010-03H
38
January 6, 2003
PLL-735 Lists 1, 2 and 3
HDSL-A and HDSL-B Alarm Thresholds Screens
Provides a means to provision the threshold crossing values for the 15 minute and 24-hour ES and UAS counts
and low margin value for the HDSL-A RTs.
Table 10, “HDSL Alarm Threshold Fields,” on page 38
lists the fields
of the HDSL-A Alarm Thresholds and the default factory values. You can view the results of these settings from
the “Performance Submenu” on page 24. The HDSL-B screen displays the data for the HDSL-B connection in
this same format.
1
Select the
HDSL-A Thrshlds
option or
HDSL-B Alarm Thrshlds
option and press
to view the screen:
Figure 32.
HDSL-A Alarm Thresholds Screen
2
With the desired field selected, type in the value for that field.
3
Press a directional key to move up or down the current column, or press
to move to the next column.
Continue until you have made all desired changes.
4
Move to the
Accept HDSL Alarm Thresholds Changes
button, press
to accept the changes.
5
Press
to return to the DICOLU main screen, or
+ to return to the PAU/PMU main menu.
Table 10.
HDSL Alarm Threshold Fields
Thresholds
Description
List 1 and 2
Defaults
List 3 Defaults
MAR
Value at which alarm is set active if margin drops equal to or less
than this threshold. Possible HDSL low margin threshold values
include any values from 0 through 15.
6
6
ES-15 MIN
Value for the HDSL 15 minute interval ES alarm. Possible threshold
values include any number from 0 to 900.
17
8
ES -24 HR
Value for the HDSL 24 hour interval ES alarm. Possible threshold
values include any number from 0 to 86400.
170
26
UAS-15 MIN Threshold value for the HDSL 15 minute interval UAS alarm.
Possible threshold values include any number from 0 to 900.
240
1
UAS-24 HR
Threshold value for the HDSL 24 hour interval UAS alarm. Possible
values include any number from 0 to 86400.
600
1
ENTER
TAB
ENTER
ESC
CTRL
R