13
Reversing Option Selections:
1. Reverse or No Reverse (preprogrammed cycles ONLY)
2. Select Reverse or Always Reverse (manually loaded cycles ONLY)
3. Basket (tumbler) Spin Time and Dwell (Stop) Time
a. Fixed in the Automatic “AUTO” Mode and
cannot be changed
.
1) Spin Time - Forward - 3 minutes, Reverse - 2 minutes.
2) Dwell (stop) Time - 5-seconds.
4. Basket (tumbler) Spin Time and Dwell (Stop) Time
a. Programmable in the Manual Mode.
1) Spin Time - programmable from 30-seconds to 120-seconds in one-second increments.
2) Dwell (stop) Time - programmable from 5-seconds to 10-seconds in one-second increments.
N. DIAGNOSTICS
Three (3) major circuits of the Phase 6 OPL microprocessor controller (computer) are monitored. They are as
follows:
1. Microprocessor Heat Sensor Circuit fault will shut the drying cycle off, and the light emitting diode (L.E.D.)
display will read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE.”
2. If there is a fault in the Door Switch Circuit, the L.E.D. display will read “LINT dOOR or MAIN dOOR.”
This display code will also appear if while a cycle is in progress the lint door or main door was opened. This
will shut the drying cycle off and no keyboard (touch pad) entry will be accepted until the main door or lint
door is closed.
a. There are two (2) red indicator lights labeled LINT and MAIN on the back side of the Phase 6 OPL
microprocessor controller (computer) to help in diagnosing this specific fault/failure.
3. If the Basket (tumbler) Fails To Rotate, a signal will appear on the L.E.D. display “Rotate Sensor Fail”
(Program Location 2 [PL 2]). Rotate Sensor
must be
active for this display.
High Temperature Protection - if the Phase 6 microprocessor controller (computer) senses that the temperature
in the basket (tumbler) has exceeded 220º F, it will shut the dryer down completely, and the default code
“BURNER SAFETY FAIL” will appear in the L.E.D. display, indicating that there is an overheating problem.
The “BURNER SAFETY FAIL” default code will be displayed until the temperature has dropped down to
220º F or lower, and then the “CLEAR/STOP”
Key
must be
pressed, at which time the L.E.D. display will
return to “REAdY.”