Soneplex

®

HDSL2 Repeater (H2RX)

Installation Instructions

)

Content

Page

INTRODUCTION

...........................................................................

1

Revision History

......................................................................

1

Trademark Information

.................................................................

1

Related Publications

...................................................................

2

Admonishments

......................................................................

2

General Safety Precautions

..............................................................

2

FCC Compliance Statement

..............................................................

3

Certification

........................................................................

3

1

GENERAL

..........................................................................

4

2

INSTALLATION

.......................................................................

6

3

MAINTENANCE LED

....................................................................

7

4

MODULE ILLUSTRATIONS AND LABEL

.......................................................

8

5

SPECIFICATIONS

.....................................................................

9

6

CUSTOMER INFORMATION AND ASSISTANCE

.................................................

10

INTRODUCTION

This publication provides a description of the HDSL2 Repeater (H2RX), installation
instructions, and pinout information.

Revision History

ISSUE

DATE

REASON FOR CHANGE

1

07/00

Original.

Trademark Information

ADC, ADC Telecommunications, Radiator, and Soneplex are registered trademarks of ADC
Telecommunications, Inc.

CLEI is a trademark of Bellcore.

Summary of Contents for SONEPLEX H2RX

Page 1: ...rtification 3 1 GENERAL 4 2 INSTALLATION 6 3 MAINTENANCE LED 7 4 MODULE ILLUSTRATIONS AND LABEL 8 5 SPECIFICATIONS 9 6 CUSTOMER INFORMATION AND ASSISTANCE 10 INTRODUCTION This publication provides a description of the HDSL2 Repeater H2RX installation instructions and pinout information Revision History ISSUE DATE REASON FOR CHANGE 1 07 00 Original Trademark Information ADC ADC Telecommunications R...

Page 2: ...seen below and are listed in descending order of severity of injury or damage and likelihood of occurrence Danger Danger is used to indicate the presence of a hazard that will cause severe personal injury death or substantial property damage if the hazard is not avoided Warning Warning is used to indicate the presence of a hazard that can cause severe personal injury death or substantial property ...

Page 3: ...certified to comply with the requirements for class A computing devices per part 15 of the FCC regulations Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with limits for a Class A digital device pursuant to Subpa...

Page 4: ...2RX is placed mid span between a Version B or later H2LXC and a Version B or later H2LXR the maximum reach can be doubled to 24 000 feet over 24 AWG wire or 18 000 feet over 26 AWG wire 14012 B H2RX HDSL2 REPEATER DANGER RISK OF ELECTRICAL SHOCK VOLTAGES UP TO 260 VOLTS MAY BE PRESENT ON TELE COMMUNICATIONS CIRCUITS FLASHING GREEN LOOPS INACTIVE GREEN ALL LOOPS ACTIVE RED EQUIPMENT FAILURE YELLOW ...

Page 5: ...30 VDC and passes the loop power on to the Version B H2LXR unit When the Version B H2LXC recognizes that the H2RX is present and the Loop Power Setting field on the H2LX Unit Configuration screen is set to AUTO it will automatically change its loop power voltage from 130 VDC to 130 VDC in order to provide sufficient power for both the H2RX and Version B H2LXR units Whenever power is present from t...

Page 6: ...eater H2RX enclosure is not grounded properly the H2RX housing may reach a high electrical potential if a short occurs This high electrical potential will result in death or severe personal injury if anyone comes in contact with the H2RX housing In addition if the H2RX is not grounded properly the lightning protection for the H2RX will be invalidated the H2RX enclosure may become electrically hot ...

Page 7: ...tic test 2 Flashing green Activating with Version B H2LXC for initial pass 130 VDC 3 Off H2RX recognized by Version B H2LXC power being configured for 130 VDC 4 Yellow Internal diagnostic test 5 Flashing green Activating with Version B H2LXC and Version B H2LXR If the Version B H2LXR is not present at this stage the LED remains in a flashing green state 6 Steady green All loops are active Version ...

Page 8: ...n B H2LXR See Table 3 for a complete listing of the pinouts 7021 D HRX HDSL REPEATER DANGER RISK OF ELECTRICAL SHOCK VOLTAGES UP TO 260 VOLTS MAY BE PRESENT ON TELECOMMUNICATIONS CIRCUITS YELLOW SELFTEST FLASHING GREEN PERFORMING ACTIVATION GREEN ALL LOOPS ACTIVE RED EQUIPMENT FAILURE 1 GND 2 NC 3 LOOP 1 RING 4 LOOP 1 TIP 5 LOOP 1 RING 6 LOOP 1 TIP 7 NC 8 LOOP 2 RING 9 LOOP 2 TIP 10 GND 11 LOOP 2 ...

Page 9: ...s Allowed Up to 35 dB Version B H2LXC to H2RX H2RX to Version B H2LXR Power Nominal Input Voltage Up to 130 VDC Max Power Consumption 6 4 watts nominal per repeater All power dissipated in the unit Dimensions 6 1 in x 2 6 in x 0 8 in 15 5 cm x 6 6 cm x 2 0 cm Weight 0 40 lb 0 18 kg Environment Operating Temperature 40 to 122 F 40 to 50 C Ambient temperature inside the apparatus case Storage Temper...

Page 10: ...allation and Operation Assistance Troubleshooting and Repair Field Assistance Product Return Department Extension 3748 E Mail repair return adc com ADC Return Authorization number and instructions must be obtained before returning products Product information may also be obtained using the ADC web site at www adc com or by writing ADC Telecommunications Inc P O Box 1101 Minneapolis MN 55440 1101 U...