Page 10

Advanced Digital Controls

Advanced Digital Controls

 

AS208-OM-V1.1

MENU 2 

MENU 2  -- EXCLUDE MODE

 EXCLUDE MODE

 

This command allows you to temporarily exclude or by-pass zones of your choice when 
arming your panel. The excluded zones will go back to normal the next time you disarm 
the panel (except 24 Hour zones which must be manually re-included). A typical example 
would be if you wanted to let your pet run around in the garage when your system is 
armed, you could choose to exclude that detector (say Zone 1) from the system.

To exclude zone 1, key in the following sequence:

MENU + 2 + 1 + ENTER

When the ENTER key is pressed the 

AWAY

indicator will flash very fast (provided that all 

zones are sealed) to indicate the exclude function is active before arming, any number of 
zones may be excluded in this manner. Press MENU 2 again to add or remove excluded 
zones. Press button 1and ENTER again and zone 1 will be included.

¤

24 hour zones (for example smoke detectors) will remain excluded until they are 

manually included again. All other excluded zones will return to normal "included" mode 
automatically the next time the panel is armed.

It is advisable to vacate the secured area before the exit delay expires

You may now ARM the panel.

  
MENU 3 

MENU 3  -- C

 C ONTROL MODE

ONTROL MODE  

  

Outputs are programmable contacts on the panel or output expander board that can be 
used to switch or power external devices on or off. 

Note: Your installer must enable this feature. 

Press the MENU 3 button 

The

SYS

indicator will be on steady

Press the number key corresponding to the output you wish to turn on i.e.-output 3 turns 
on water heating. 

Press the 3 key, the 3 indicator will illuminate indicating the output is on. 

Press the ENTER key to confirm the operation and return to normal keypad function

To check what outputs are on simply press the MENU 3 keys again, indicator 3 will be 
illuminated, pressing the 3 & ENTER keys again will toggle the output off. 

www.msealarms.com.au

Summary of Contents for Ultra-8

Page 1: ...Control Panel Operators Manual TO SUIT AS208 KEYPAD Advanced Digital Controls AS208 OM 1 2 www msealarms com au ...

Page 2: ...ng mechanical recording or otherwise without the written permission of Advanced Digital Controls NZ Ltd Notice of Liability While every precaution has been taken in the preparation of this document neither Advanced Digital Controls NZ Ltd nor any of its official representatives shall have any liability to any person or entity with respect to any liability damage or loss caused or alleged to be cau...

Page 3: ...efinitions 6 Arming The Panel In AWAY Mode 6 Arming The Panel In STAY Mode 7 Disarming the Panel 7 Adding or Deleting Codes 7 Menu 1 Playback 8 Memory Event List 9 Menu 2 Exclude Mode 10 Menu 3 Control Mode 10 Menu 4 Buzzer Pitch 11 Menu 5 Day Alarm ON OFF 11 Menu 6 Fault Analysis 12 Hold Up Duress Alarm 12 Acknowledging Domestic Voice Alarm Messages 12 Voice Board Operating Instructions 13 www ms...

Page 4: ... degree of reliability This manual will guide you through the operation and programming of your Ultra 8 alarm panel Add on features like the WR40 RX40 radio receivers that can operate any of the 4 outputs or arm disarm your panel with up to 8 keyfob radio pendants The auto dialler on your panel can be set up to send high speed signals to a monitoring station or domestic dial sending an Alarm tone ...

Page 5: ...The SYS indicator is used to inform you of events in the panel memory Indicator Definition FLASHING A new event is in progress ON The new event has cleared OFF No new events have occurred FAULT INDICATOR The FAULT indicator is used to inform you when an tamper alarm occurs Indicator Definition FLASHING Tamper or Panic alarm in progress ON Tamper acknowledged but not cleared OFF No alarm condition ...

Page 6: ...ands as listed on the page 7 ê ê Button This is used for different programming options OPTIONAL LABELS OPTIONAL LABELS PANIC 1 3 Buttons Simultaneously This will cause a PANIC Alarm This will sound the sirens and if connected to a monitoring station inform them of a Panic situation FIRE 4 6 Buttons Simultaneously This will cause a FIRE Alarm This will sound the sirens and if connected to a monitor...

Page 7: ...e keypad See page 8 for further information Menu 2 Exclude Mode This command allows you to temporarily exclude or by pass zones of your choice when arming your panel See page 10 for further information Menu 3 Control Mode This command will allow you to switch Day Zones On Off or to control outputs See page 10 for further information Menu 4 Buzzer Pitch This command allows you to change the pitch o...

Page 8: ...e a code to STAY arm the panel To do so press STAY and enter your code followed by the ENTER key When arming STAY mode all exit and entry delays will apply as programmed however if the ENTER button is pressed after arming STAY mode then all exit and entry delays will be cancelled for that armed cycle making everything instant DISARMING THE PANEL DISARMING THE PANEL 3 6 Digit Code To disarm the pan...

Page 9: ... STAY indicator MENU 1 MENU 1 MEMORY PLAYBACK MEMORY PLAYBACK This event memory is displayed via the keypad with the most recent event shown first and subsequent events following in descending order from newest to oldest Each event is separated by a beep tone There are a number of events which are stored in memory which do not have a specific indicator associated with them such as Panic and Duress...

Page 10: ...lashing WIRELESS KEYFOB LOW BATTERY Wireless Keyfob User 1 8 FAULT LED s 1 8 On Steady Flashing PANIC BUTTONS 1 3 PRESSED TOGETHER Keypad Panic SYS Flashing FIRE ALARM BUTTONS 4 6 PRESSED TOGETHER Keypad Fire SYS AWAY Flashing Flashing MEDICAL ALARM BUTTONS 7 9 PRESSED TOGETHER Keypad Medical SYS STAY Flashing Flashing WIRELESS KEYFOB PANIC Wireless Keyfob User 1 8 SYS LED 1 8 Flashing Flashing AR...

Page 11: ...d ENTER again and zone 1 will be included 24 hour zones for example smoke detectors will remain excluded until they are manually included again All other excluded zones will return to normal included mode automatically the next time the panel is armed It is advisable to vacate the secured area before the exit delay expires You may now ARM the panel MENU 3 MENU 3 C CONTROL MODE ONTROL MODE Outputs ...

Page 12: ...ess MENU 4 5 ENTER This set the buzzer pitch to medium pitch MENU 5 MENU 5 DAY ALARM ON OFF DAY ALARM ON OFF The Day Alarm is a zone that can be used to operate a buzzer or light to let you know that you have a visitor when the alarm is disarmed Press MENU 5 to switch the Day Alarm ON OFF The buzzer will beep 3 times to let you know that you have switched the Day Alarm ON The STAY button will flas...

Page 13: ... UP DURESS ALARM The duress digit is a number from 1 9 To create a duress alarm the duress digit must be pressed before the code to disarm ie If the user code is 2580 and the duress digit is 5 then entering a code of 52580 ENTER would create a duress alarm The sirens won t sound but the dialler would dial to the Monitoring Station and report a DURESS ALARM Please ask your installer to set the dure...

Page 14: ...l is very similar with the exception that the output number you wish to control must be entered in after the valid 4 digit code e g if the output control code was 2 5 8 0 and you wanted to control output 2 then the code 2 5 8 0 2 must be entered in at the remote telephone Once again if this was a valid code to control the outputs the panel will respond with the voice message relating to the curren...

Page 15: ...allation Date Warranty Expires Warranty Expires Entry Exit Timers Entry Exit Timers seconds Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Exit STAY DAY Zone Descriptions Zone Descriptions MODE ALARM Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Hold Hold Up Duress Alarm Digit Up Duress Alarm Digit Notes Notes www msealarms com au ...

Reviews: