PA 358
Technical description Chapter 5
8
5.2.1 Jumper
settings
IMPORTANT!
The jumper settings depend on the version of the board (voltage or
current output channels)
The following jumper settings are given for channel 0.The settings are identical for
all channels on the board. See the corresponding jumper designations in fig. 5-2.
The watchdog function is valid for all channels.
Table 5-1: Jumper settings - Channel 0
Jumper
Settings
Functions
Settings at
delivery
J1
Set
Value of the DAC I after reset
Unipolar zero
Unipolar zero
Not set
Value of the DAC I after reset
Bipolar zero
J2
Output range for channel 0
Bipolar
Output range for channel 0
Unipolar
Unipolar
J4
Output range for channel 0
0-10 V
0-10 V
Output range for channel 0
0-5 V
J25, J26,
J41
Output range for channel 0
4-20 mA
4-20 mA
Output range for channel 0