Technical data
APCI-3003
4.3
Options
The board
APCI-3003
is available in the following options:
PC-Diff.:
................................................... Current input for 1 differential channel
................................................................... (0-20 mA, 4-20 mA)
Measuring range
With 16-bit resolution
0 mA
Corresponds 0 digit
4 mA
Corresponds 13107 digits
20 mA
Corresponds 65535 digits
Note:
At 4-20 mA a reduced precision is possible.
4.4
Limit values
Max. Altitude: ........................................... up to 2000 m above sea level
Operating temperature: ............................. 0 to 60
°
C
Storage temperature: ................................. -25 to 70
°
C
Relative humidity at indoor installation
50% at +40 °C
80% at +31 °C
Minimum PC requirements:
PCI BIOS from Version 1.0
Bus speed: ................................................. < 33 MHz
Operating system: ..................................... Windows 2000, XP, Linux (other
operating systems on request)
Slot:............................................................ PCI 5 V or PCI 3.3 V, 32-bit
Current consumption (without load): ........ typic. See table ± 10%
APCI-3003
+ 5 V from PC
1.55 A
4.4.1
Analog inputs
Number of analog inputs: .......................... 4 differential channels
Analog resolution: ..................................... 16-bit, 1 in 65535
Max. sampling rate: ................................... 400 kHz
Data transfer: ............................................. data to the PC via FIFO buffer,
via I/O commands,
interrupt at EOC or DMA transfer at
EOC
12