Mounting and connection
MSX-ilog-xx-xx
www.addi-data.com
19
ADDI-DATA
®
PARTNER FÜR PRÄZISION
3.2.4 Analog inputs
MSX-ilog-AI-16, MSX-ilog-3122
To each M12 female connector, one sensor can be connected. One analog input consists of input + and
input -. Optionally, a 24 V voltage is available to supply a sensor if required.
Table 3-5: Pin assignment: Analog inputs
Pin No.
Female connector,
5-pin, M12
Cable
Lead colour
1
24 V
brown
2
Differential input -
white
3
GND
blue
4
Differential input +
black
5
not connected
grey