Web interface: Quick access to the Ethernet data logger
MSX-ilog-xx-xx
www.addi-data.com
42
ADDI-DATA
®
PARTNER FÜR PRÄZISION
Fig. 4-14: Network: Ethernet
NOTICE!
Once you have changed a parameter, you have to click on the
respective “Save” button to save your settings.
1) Configuration
In the field “Network hostname”, you can enter up to 64 characters of any kind. When you click on
“Save”, this change takes immediately effect.
In the field “Network address”, enter an IP address in the form of “198.168.99.99” and click on
“Save”.
The new value will be used when the Ethernet data logger is restarted.
The following parameters can also be set:
•
Netmask:
IP network mask for this interface; default value of the usual class A, B or C network
mask (as derived from the interface IP address) or any value
•
Gateway:
is added to the routing table; valid or symbolic IP address, or 0.0.0.0 if not available
•
Broadcast address:
Broadcast address of the protocol for this interface; in case of the value
0.0.0.0, it is automatically computed from IP address and network mask; optional field
2) DHCP server
The Ethernet data logger has a DHCP server which is used to automatically assign an IP address to a PC
that has just connected to the DHCP server.
The DHCP server is activated for the Ethernet network when you click on the button “Use DHCP
server”. The range of the IP addresses to be entered in the “Start address” and “End address” fields
must correspond to the IP address of the Ethernet data logger, i.e. it must be on the same network.