Piston Rod and End Plug/Seal and Spacer Replacement 

1.

 

Move the integral stainless steel bypass to the bypass position. 

2.

 

Relieve the water pressure in the Iron Genie by holding down the Extra Cycle button for 5 

seconds. Once in the “BW” cycle pressure will be relieved.  

3.

 

Push extra cycle button to move control valve to “BD” cycle. 

4.

 

Push extra cycle to return the control valve to the service position (time of day on display). 

5.

 

Unplug Power Head from electrical outlet. 

6.

 

Remove the control valve back cover.  

7.

 

Remove black screw and silver washer at drive yoke on piston rod.  

8.

 

Remove two silver timer mounting screws. 

9.

 

Lift off entire Power Head assembly. 

10.

 

Remove three silver screws on stainless steel end plug retainer plate. 

11.

 

Remove end plug retainer plate. 

12.

 

Pull up on end of piston rod yoke until piston is out of valve. 

13.

 

Remove five rubber seals and four plastic spacers from valve body. 

14.

 

Replace the five rubber seals and four plastic spacers. 

15.

 

Take the piston assembly with the new piston rod and cap and push piston into valve by means 

of the end plug.  DO NOT pull up on piston rod. 

16.

 

Replace end plug retainer plate 

17.

 

Replace three silver screws on end plug retainer plate. 

18.

 

Twist yoke in a clockwise direction to align it with main drive gear. 

19.

 

Put Power Head on top of control valve. Be sure drive pin on main gear engages slot in drive 

yoke. 

20.

 

Replace black screw and silver washer at drive yoke.  

21.

 

Replace the 2 silver timer mounting screws. 

22.

 

Return bypass to service position. Water pressure automatically builds in tank. 

23.

 

Check for leaks. 

24.

 

Plug electrical cord into outlet. 

25.

 

Set time of day and cycle the control valve through an immediate regeneration to assure proper 

function. 

26.

 

Replace the Power Head back cover. 

 

 

 

 

 

 

 

Summary of Contents for IRON GENIE1

Page 1: ...IRON GENIE Chemical Free Iron Sulfur Reduction...

Page 2: ...FLOW RATE GPM PEAK FLOW RATE GPM BACKWASH RATE GPM TIG56SXT SI 10X54 1 0 2 5 3 7 7 0 TIG56SXT SI ECM 13X54 2 0 4 5 7 0 11 0 Peak flow rates are non continuous for residential use only Flow rates are s...

Page 3: ...r How Does It Work The Iron Genie adds oxygen to the incoming raw water by passing the water through a pressurized air head in the media tank This will begin to convert dissolved elements such as iron...

Page 4: ...pass position indicated by small pointer on handle Turn on main water supply 5 SLOWLY place the bypass in service position and let water flow into the mineral tank 6 Open the nearest cold water faucet...

Page 5: ...ion The unit empties of water and is filled with air During this cycle water will run to drain There is a slight delay at the start of the cycle while the pressure of the air within the tank reaches a...

Page 6: ...s and hold the Up or Down buttons until the programming icon replaces the service icon and the parameter display reads TD Adjust the displayed time with the Up and Down buttons When the desired time i...

Page 7: ...h and hold the Up and Down Arrow Buttons for 7 seconds Press the Extra Cycle Button once to advance to next parameter 1 DF GAL US Gallon Display Format 2 VT dF1b Down flow Single Backwash 3 CT tc Time...

Page 8: ...advance on main display If not replace Power Head Assembly Unit does not draw air in BD cycle Injector is plugged Clean or replace injector throat and nozzle Injector screen is plugged Clean or replac...

Page 9: ...e and system type are set correctly with regard to the unit itself Step the unit through a manual regeneration and verify that it functions correctly If the error re occurs unplug the unit and contact...

Page 10: ...Power Head Assembly...

Page 11: ...lve 5600 12 1 12037 Washer Plain 10 18 8 SS 13 1 40214 Screw Hex Wsh 6 20 x 3 4 14 2 19080 Spring Compression 6700 15 2 13300 Ball 1 4 Stainless Steel 16 1 42933 Gear Main Drive SXT 17 1 13547 Strain...

Page 12: ...CONTROL VALVE ASSEMBLY...

Page 13: ...2 O ring Brine Spacer 21 1 13303 O ring Injector Cover 22 1 13163 Injector Body 23 1 10913 x Injector Nozzle specify size 24 1 10914 x Injector Throat specify size 25 1 10227 Injector Screen 26 1 1316...

Page 14: ...o Description 1 1 17290 Bypass Valve Body 3 4 1 13399 Bypass Valve Body 1 2 1 14105 Seal Bypass 3 1 11972 Plug Bypass 4 1 11978 Side Cover 5 1 13604 01 Label 6 8 15727 Screw 7 1 11986 Side Cover 8 1 1...

Page 15: ...Assembly 13446 41 End Plug Assembly Green 60125 02 Seal and Spacer Kit Low Drive Force 10913 2 Injector Nozzle 2 Blue 10914 2 Injector Throat 2 Blue 10227 Screen 42933 Main Drive Gear 60032 Brine Valv...

Page 16: ...bypass to the bypass position 2 Relieve the water pressure in the Iron Genie by holding down the Extra Cycle button for 5 seconds Once in the BW cycle pressure will be relieved 3 Push extra cycle butt...

Page 17: ...alve from injector body 13 Discard o ring at bottom of brine valve hole in injector body 14 Install new o ring at bottom of brine valve hole in injector body 15 Press brine valve into brine valve hole...

Page 18: ...end of piston rod yoke until piston is out of valve 13 Remove five rubber seals and four plastic spacers from valve body 14 Replace the five rubber seals and four plastic spacers 15 Take the piston a...

Reviews: