Troubleshooting 

Error 
Code 

Error 

Type 

Cause 

Reset and Recovery 

Cam 

Sense 

Error 

The valve drive took 

longer than 6 minutes 

to advance to the 

next regeneration 

position. 

Unplug the unit and examine the power head. Verify that all 
cam switches are connected to the circuit board and 
functioning properly. Verify that the motor and drive train 
components are in good condition and assembled properly.  
Check the valve and verify that the piston travels freely. 
Replace /reassemble the various components as necessary.                                                                          

Plug the unit in and observe its behavior. The unit should cycle 
to the next valve position and stop. If the error re-occurs, 
unplug the unit and contact your water treatment dealer. 

Cycle 

Step 

Error 

The control 

experienced an 

unexpected cycle 

input 

Unplug the unit and examine the power head. Verify that all 
cam switches are connected to the circuit board and 
functioning properly. Enter Master Programming mode and 
verify that the valve type and system type are set correctly 
with regard to the unit itself. 

Step the unit through a manual regeneration and verify that it 
functions correctly. If the error re-occurs unplug the unit and 
contact you water treatment dealer. 

Regen 

Failure 

The system has not 

regenerated for more 

than 99 days 

Perform a manual regeneration to reset the error code. 

Enter the Master Programming Mode and verify that the unit 
is configure properly. 

Memory 

Error 

Control board 

memory failure 

Perform a Master Reset and reconfigure the system via Master 
Programming mode. After reconfiguring the system, step the 
valve through a manual regeneration. If the error re-occurs 
unplug the unit and contact your local water treatment dealer. 

UD 

Upper 

Drive 

Sync 

Power failure install 

programming change 

Valve will automatically recover. 

 

Resets 

Soft Reset

: Press and hold the Extra Cycle and Down Buttons for 25 seconds while in    normal service mode. 

This resets all parameters.  Check and verify all parameters in master programming. 

 

Master Reset: 

Hold the Extra Cycle button while powering up the unit. This resets all parameters. Check and 

verify all parameters in mater programming 

 

 

Summary of Contents for IRON GENIE1

Page 1: ...IRON GENIE Chemical Free Iron Sulfur Reduction...

Page 2: ...FLOW RATE GPM PEAK FLOW RATE GPM BACKWASH RATE GPM TIG56SXT SI 10X54 1 0 2 5 3 7 7 0 TIG56SXT SI ECM 13X54 2 0 4 5 7 0 11 0 Peak flow rates are non continuous for residential use only Flow rates are s...

Page 3: ...r How Does It Work The Iron Genie adds oxygen to the incoming raw water by passing the water through a pressurized air head in the media tank This will begin to convert dissolved elements such as iron...

Page 4: ...pass position indicated by small pointer on handle Turn on main water supply 5 SLOWLY place the bypass in service position and let water flow into the mineral tank 6 Open the nearest cold water faucet...

Page 5: ...ion The unit empties of water and is filled with air During this cycle water will run to drain There is a slight delay at the start of the cycle while the pressure of the air within the tank reaches a...

Page 6: ...s and hold the Up or Down buttons until the programming icon replaces the service icon and the parameter display reads TD Adjust the displayed time with the Up and Down buttons When the desired time i...

Page 7: ...h and hold the Up and Down Arrow Buttons for 7 seconds Press the Extra Cycle Button once to advance to next parameter 1 DF GAL US Gallon Display Format 2 VT dF1b Down flow Single Backwash 3 CT tc Time...

Page 8: ...advance on main display If not replace Power Head Assembly Unit does not draw air in BD cycle Injector is plugged Clean or replace injector throat and nozzle Injector screen is plugged Clean or replac...

Page 9: ...e and system type are set correctly with regard to the unit itself Step the unit through a manual regeneration and verify that it functions correctly If the error re occurs unplug the unit and contact...

Page 10: ...Power Head Assembly...

Page 11: ...lve 5600 12 1 12037 Washer Plain 10 18 8 SS 13 1 40214 Screw Hex Wsh 6 20 x 3 4 14 2 19080 Spring Compression 6700 15 2 13300 Ball 1 4 Stainless Steel 16 1 42933 Gear Main Drive SXT 17 1 13547 Strain...

Page 12: ...CONTROL VALVE ASSEMBLY...

Page 13: ...2 O ring Brine Spacer 21 1 13303 O ring Injector Cover 22 1 13163 Injector Body 23 1 10913 x Injector Nozzle specify size 24 1 10914 x Injector Throat specify size 25 1 10227 Injector Screen 26 1 1316...

Page 14: ...o Description 1 1 17290 Bypass Valve Body 3 4 1 13399 Bypass Valve Body 1 2 1 14105 Seal Bypass 3 1 11972 Plug Bypass 4 1 11978 Side Cover 5 1 13604 01 Label 6 8 15727 Screw 7 1 11986 Side Cover 8 1 1...

Page 15: ...Assembly 13446 41 End Plug Assembly Green 60125 02 Seal and Spacer Kit Low Drive Force 10913 2 Injector Nozzle 2 Blue 10914 2 Injector Throat 2 Blue 10227 Screen 42933 Main Drive Gear 60032 Brine Valv...

Page 16: ...bypass to the bypass position 2 Relieve the water pressure in the Iron Genie by holding down the Extra Cycle button for 5 seconds Once in the BW cycle pressure will be relieved 3 Push extra cycle butt...

Page 17: ...alve from injector body 13 Discard o ring at bottom of brine valve hole in injector body 14 Install new o ring at bottom of brine valve hole in injector body 15 Press brine valve into brine valve hole...

Page 18: ...end of piston rod yoke until piston is out of valve 13 Remove five rubber seals and four plastic spacers from valve body 14 Replace the five rubber seals and four plastic spacers 15 Take the piston a...

Reviews: