background image

10-8. Fast Copy

When this setting is ON, the duplicator will attempt to copy the source drive's contents
instead of the entire disk. Also controls Compare function. Default setting is OFF.

NOTE: Target drive size is still required to be equal to or greater than source. Only works
with source drives formatted using Master Boot Record. If the source drive has a boot
record other than MBR, the entire disk will be copied as if Fast Copy were OFF. If the
source drive is formatted with a Master Boot Record and contains only FAT32 or NTFS
partitions,  identical  partitions  will  be  created  on  the  target(s)  and  only  the  files  will  be
copied. If the source drive with MBR format includes partitions other than FAT32 or NTFS,
all sectors of all partitions (including FAT32 and NTFS) will be duplicated.

Enabling Fast Copy may not produce bootable duplicates.

10-9. Auto Start Drive

When source drive is present, inserting a target drive will cause copy process to begin
automatically. Default setting is OFF.

10-10. Auto Start Timer

Sets delay in time after target insertion before beginning auto copy process if Auto Start
Drive is ON. Default setting is OFF (no delay).

10-11. Tolerance Size

Sets the minimum target size in percentage compared to the source that is allowed to use
for copying. Default is 100% (equal in size).

NOTE:  Leaving  this  setting  at  100%  or  using  for  minor  adjustments  only  is  strongly
recommended.  Permitting  target  size  less  than  source  size  may  result  in  inaccurate
copies.

10-12. BootTime Delay

This option is used to set boot delay time. Default setting is 5 seconds.

10-13. Quick Compare

Sets  Compare  function  to  stop  after  a  small  amount  of  data  has  been  verified,  up  to
100MBytes. Default setting is OFF.

10-14. Copy with Size

Causes  duplicate  drive  to  report  to  an  operating  system  the  exact  same  total  size  as
source  when  copy  is  complete.  Works  only  on  drives  formatted  using  a  Master  Boot
Record. Default setting is OFF.

5

www.addonics.com

Technical Support (M-F 8:30 am – 6:00 pm)

Summary of Contents for MSHDU11T

Page 1: ...port If you need any assistance to get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com support query ...

Page 2: ...arts functions ESC key Used to exit sub menus discard option changes or cancel functions when held 1 www addonics com Technical Support M F 8 30 am 6 00 pm mSATA to SATA Adapter Quantity 12 Power Cord U S Version shown WARNING Please remember to set the power supply to your local outlet voltage prior to plugging in the power cord Failure to do so may damage the power supply ...

Page 3: ...ep 6 Close the door on the drive bay It should also give little resistance don t force it As soon as the drive is in position it will power up Phone 408 453 6212 Email www addonics com support query 2 Step 1 Insert the mSATA SSD into the mSATA connector on the PCB Step 2 Push down the other end of the mSATA SSD until it is latched securely by the hold down clip NOTE The completed flash drive has t...

Page 4: ...he ports then copies from the source to any targets found 2 Async Copy HDD Scans the ports then copies from the source to any targets found More drives may be added before the process is complete they will begin the process as soon as they are detected 3 Compare HDD Scans the ports then any targets found will be compared to the source 4 Async Compare Scans the ports then any targets found will be ...

Page 5: ...Menu Only available by holding ESC on any Main Menu option See Advanced Setup Options Setup options 10 1 Language Use this option to select the language of the system currently only English is supported 10 2 Copy Size Controls how much of the source drive to use for copy operations in percentage Default setting is ALL 100 10 3 Startup Menu Sets the first menu option to appear after boot Default se...

Page 6: ...resent inserting a target drive will cause copy process to begin automatically Default setting is OFF 10 10 Auto Start Timer Sets delay in time after target insertion before beginning auto copy process if Auto Start Drive is ON Default setting is OFF no delay 10 11 Tolerance Size Sets the minimum target size in percentage compared to the source that is allowed to use for copying Default is 100 equ...

Page 7: ...tire disk before proceeding Providing a drive that is as small as possible is strongly recommended 11 04 Quick Erase HDD Scans the ports then quickly erases all sectors on all connected drives 11 05 Full Erase HDD Scans the ports then completely erases all sectors on all connected drives 11 06 H W Diagnostic Starts comprehensive tests for Ram LCD buttons ports and Flash 11 07 Load Default Resets a...

Page 8: ...Contact Us www addonics com Phone 408 573 8580 Fax 408 573 8588 Email http www addonics com sales query ...

Reviews: