Chapter 4.
Power Supply and Check
Operational Status
AP-MG3000N Gateway Booting and Operation
When power is supplied, the system is booted as described below..
z
VoiceFinder AP-MG3000 Gateway performs a self-test and checks
basic operations of the CPU, the memory and interfaces
.
z
The boot loader is executed, and the boot loader seeks for proper
software image files. The boot loader loads the broadcasting system
software from the flash memory
.
z
If the boot loader cannot find proper software image file from the flash
memory, the boot loader stands by in the boot mode until it receives
proper software from the remote system. (At this time, the boot
loader can download software through TFTP or FTP protocol
.)
z
When the software is loaded, the broadcasting system starts to operate
according to configuration information. However, if there is no
configuration information, it operates according to the default values,
and in this case, the operator shall set up related items for normal
operation of the network
.
After connecting all the interfaces, supply the power to VoiceFinder AP-
MG3000 Gateway. Supply the power after connecting the adapter to
VoiceFinder AP-MG3000 Gateway. Do not connect the adapter to the power
supply before connecting it to the gateway. Also, use 110V adapter in case
the power supply is 110V. However, the gateway detects both 110V and
220V, so there is no additional setting required
.