background image

 
 

   SABRE

 RANGER 5000 User Guide

 

 

 

© 2017 Addvalue Innovation Pte Ltd. All rights reserved. 

46 

 

11.3.4.4 Power Saving 

 

 

 

      
          Figure 58 

 

Summary of Contents for SABRE RANGER 5000

Page 1: ...Version 1 0 draft Date 11 Sep 2017 SABRE RANGER 5000...

Page 2: ...2 2 Inbox 38 11 2 3 Sent 39 11 2 4 Draft 39 11 3 Settings 40 11 3 1 Accounts 40 11 3 2 Ethernet 41 11 3 3 Security 42 11 3 4 Terminal Settings 43 11 3 4 1 Reboot Terminal 43 11 3 4 2 Factory Reset 43...

Page 3: ...s names or product names referenced in this publication are the property of their respective owners Addvalue Innovation Pte Ltd neither endorses nor otherwise sponsors any such products or services re...

Page 4: ...technician for help IMPORTANT NOTE EXPOSURE TO RADIO FREQUENCY RADIATION This Device complies with FCC IC radiation exposure limits set forth for an uncontrolled environment The Antenna used for this...

Page 5: ...completing the upgrade process of the CE RED tests Mobile Earth Stations MES 1668 1670 MHz is under restricted usage under ECC Decision ECC DEC 04 09 for EU Countries User Operator shall check with l...

Page 6: ...rovide reliable and stable BGAN connectivity continuously for long period of time without user intervention It is fully compatible with the Remote Terminal Manager RTM or Inmarsat M2M platform which a...

Page 7: ...2017 Addvalue Innovation Pte Ltd All rights reserved 7 2 Quick Reference Figure 2 The SABRE RANGER 5000 has a NPT inch hole for installing a conduit fitting or a cable gland on the bottom part of the...

Page 8: ...screws from the protective cover and loosen the Rotation Point screw See figure 3 Figure 3 2 Rotate the protective cover in a clockwise direction 3 Open the SIM card cover and rotate in a clockwise di...

Page 9: ...lue Innovation Pte Ltd All rights reserved 9 4 Slot the SIM card into the SIM card holder in the orientation as shown on figure 5 Figure 5 5 Insert the SIM card until it clicks into place 6 Rotate and...

Page 10: ...Cables and Wires The SABRE RANGER 5000 has a NPT inch hole for installing a conduit fitting or a cable gland at the bottom part of the casing to connect all the wires See appendix B for information a...

Page 11: ...is Power supply input supports a range of voltages from 10 8 to 32Volts The terminal requires 20W when transmitting and 6W when receiving Use two AWG16 wires for power connection if the cable length i...

Page 12: ...port This is a user configurable port The user can configure this port to be any of the following RS232 RS485 full duplex RS485 half duplex RS232 Use Belden cable no 9533 or equivalent for 3 wire RS2...

Page 13: ...OP4 of CON802 A low side driver will pull the signal to ground when active An output can sink up to 400mA of current Lo w Side Driver Figure 12 Digital input There are 4 digital inputs They are connec...

Page 14: ...specifications of the Digital input Terminal Data Ready TDR output This is a digital output The TDR output is connected to pin 13 TDR of CON801 The signal ground is connected to pin 1 GND of CON802 T...

Page 15: ...ather all the connected cables and wires 2 Loop the cable tie into the cable tie hole in the terminal before fastening to secure the wires in place so that they will not slip off its connectors See fi...

Page 16: ...ABRE RANGER 5000 User Guide 2017 Addvalue Innovation Pte Ltd All rights reserved 16 4 Secure the conduit tightly to the adaptor to prevent water from getting into the conduit and the terminal Figure 1...

Page 17: ...e protective cover anti clockwise to the closed position 2 Tighten the six black screws including the rotation point screw with a flat blade screw driver NOTE For ingress protection it is important to...

Page 18: ...Accessories Mounting Bracket Figure 18 Parts List ITEM DESCRIPTION QTY 01 Socket Head Cap Screws M8 x 120mm Full thread 4 02 Flat Washers M8 12 03 Saddle Clamps 2 04 Bracket Wall 185 x 90 x 100 mm 1...

Page 19: ...ure 19 and its enlarged view 3 Align the four holes and fasten to Sabre Ranger 5000 terminal using the washers 4x and the socket head cap screws M8 x 14mm 4x with a hex L key 4 Align the bracket wall...

Page 20: ...mn to mount the SABRE RANGER 5000 terminal NOTE The mounting bracket is designed to be mounted on a 1 to 3 inch diameter pole 2 Mount the pre assembled terminal to the pole TIP If you have a long cond...

Page 21: ...pole by first turning in the screws and washers at the position and and then turn in the screws and washers at the position and for easy installation See figure 22 Figure 22 5 Tighten the screws to se...

Page 22: ...ANGER 5000 terminal must be firmly connected to the earth ground by using a short and low impedance wire Figure 24 1 Unscrew one of the four mounting screws at the back of the terminal 2 Insert the ea...

Page 23: ...n on Navigate to the Web Console for more details Azimuth and Elevation are angles used to define the apparent position of an object in the sky relative to a specific observation point In this case we...

Page 24: ...E RANGER 5000 User Guide 2017 Addvalue Innovation Pte Ltd All rights reserved 24 4 Insert the M5 bolt to lock the required position and tighten it to secure the angle of elevation See figure 27 Figure...

Page 25: ...d connect the Ethernet cable to your laptop PC Figure 28 2 When the terminal is powered up all the Antenna Pointing LEDs will flash briefly and goes off This indicates the terminal is ON 3 After a sho...

Page 26: ...o assisted pointing mode In this mode a buzzer will emit an audio tone with its pitch changing according to the strength of the global beam signal The buzzer is disabled by default To enable the buzze...

Page 27: ...l strength will gradually increase This is indicated by lighting up more LEDs and gradually increasing pitch of the audio tone 4 You may also verify the signal strength through the Web Console i Open...

Page 28: ...2 The Antenna Pointing LEDs flash in sequence during the network registration NOTE The SABRE RANGER 5000 terminal activates a data connection automatically by default Auto Network Registration When t...

Page 29: ...HTTP Filters Port Forwarding Data Settings Compose Inbox Sent Draft Accounts Ethernet Ethernet Ethernet Settings DHCP MAC Filtering Security Terminal PIN SIM PIN Terminal Settings Reboot Terminal Fac...

Page 30: ...connection NOTE Signal strength must be 42dB or above for the terminal to successfully connect or register to the network Signal strength can be improved by pointing more accurately If the signal stre...

Page 31: ...t of profiles to be the default primary profile and connection type Figure 33 Click Edit to modify the data profile You can create your customized primary profile Figure 34 NOTE Please note that the S...

Page 32: ...ied by your service provider if required Static IP Address APN By default a Dynamic IP Address is selected To use a Static IP Address i Select Static IP Address and enter the APN address and password...

Page 33: ...tab click Add to add new rules Figure 37 ii Enter your desired rule name and fill in the necessary information iii Select Action Reject to reject the incoming packet iv Click Apply to the save the ne...

Page 34: ...gate to Menu Data Firewall HTTP Filters to enable the filtering based on the hostname or the keywords Follow these steps to apply hostname filtering i Select Enabled Figure 39 ii Click Update to modif...

Page 35: ...e new port forwarding rule Figure 41 Follow these steps to add a new forwarding rule i Click Add Figure 42 ii Enter the Incoming Port number range in the provided space If only one number repeat the n...

Page 36: ...ction upon power up It also helps to re establish the PDP connection due to network deregistration or any reason other than user intervention Navigate to Menu Data Data Settings to configure the data...

Page 37: ...se page Figure 44 i Enter the recipient s phone number in the Phone no box Type the message in the text editor box ii Click Send to send the SMS iii To save an unsent SMS click Save and the unsent SMS...

Page 38: ...e text box iv Click Send to send the SMS Forward an SMS from the Inbox i Select the SMS you plan to forward and click Forward ii The inbox console will switch over to Compose mode Enter your reply in...

Page 39: ...Figure 46 11 2 4 Draft Stored SMSs are saved inside the draft folder Navigate to SMS Draft to view Draft SMSs Send a draft SMS i Select the draft SMS you plan to send and click Send ii The SMS will be...

Page 40: ...tings Accounts to create or edit an account for Web Console access By default the password for admin is 1234 You are recommended to change the admin password for security reasons Only one User and one...

Page 41: ...iltering Reject List i Select Enabled to enable this feature ii Select Reject List to block the devices to access the terminal iii Enter the MAC address into the provided space and click Add to update...

Page 42: ...and click Update PIN Figure 51 NOTE The same password is used for the Factory Reset PIN SIM PIN If the security feature is enabled a prompt requests you to enter the SIM PIN each time you power up you...

Page 43: ...Settings Reboot Terminal to reboot the terminal Figure 53 11 3 4 2 Factory Reset Navigate to Menu Settings Terminal Settings Factory Reset to factory reset the terminal Enter security code for factor...

Page 44: ...e upgrade allows you to update the terminalwith the latest operating software The terminal has to be in Safe Mode for firmware upgrading Navigate to Menu Settings Terminal Settings Firmware Upgrade to...

Page 45: ...eb Console remote access Navigate to Menu Settings Terminal Settings Remote Access to enable the Web Console remote access Figure 56 i Select Enabled to enable the remote access feature ii Select Disa...

Page 46: ...SABRE RANGER 5000 User Guide 2017 Addvalue Innovation Pte Ltd All rights reserved 46 11 3 4 4 Power Saving Figure 58...

Page 47: ...ture Figure 59 i Select Enabled to enable the ciphering feature ii Select Disabled if you do not need the feature iii Click Apply for the new configuration to take effect 11 3 4 6 Facility Lock Naviga...

Page 48: ...the terminal can verify whether the connection is still available As long as the terminal is able to ping any of the IP addresses the watchdog will not trigger a system reboot NOTE In Single user Rou...

Page 49: ...ut min used to disconnect an idle TCP connection By default it is configured as 10 minutes 0 minute TCP connection will not be disconnected due to an idle TCP connection 1 to 99 minutes Based on the T...

Page 50: ...l allows 2 to 4 TCP connections to open the serial port simultaneously i Select Enabled to enable the Periodic Reboot ii Select Disabled if you do not need the feature iii Enter the IP addresses with...

Page 51: ...er applications Data TCP port Acts as the TCP port that the data actually transmits through this port After establishing the connection data can be transmitted in both directions from PC to port 9001...

Page 52: ...remote access users need to know the Global IP address of the terminal This information can be retrieved through Data Logs By default the terminal accepts all the IP addresses Host Allow IP address ra...

Page 53: ...nfiguration Reference Table Navigate to Menu Settings Terminal Settings Backup Restore to save or restore the configuration settings Backup configuration settings i Click Backup ii The settings will b...

Page 54: ...take effect iii Navigate to Menu Settings Terminal Settings Reboot Terminal and click Reboot terminal to reboot the terminal for the new settings to take effect NOTE After set the port number e g 20...

Page 55: ...vation Pte Ltd All rights reserved 55 11 3 4 12 GNSS Selection Navigate to Menu Settings Terminal Settings GNSS Selection i Select your GNSS option ii Click Update for the setting and reboot to take e...

Page 56: ...ice provider Logs Navigate to Menu Settings Terminal Info Logs to view the Event Log or Error Log of the terminal Click Export all Logs in order to export the logs Data Log Navigate to Menu Settings T...

Page 57: ...SMS from the terminal This may incur airtime charges depending on the service provider iv Enter the SMS password for the remote control v Click update for the feature to take effect NOTE Refer to Sab...

Page 58: ...inal Settings Firmware Upgrade to perform a firmware upgrade Your terminalwill reboot in Safe Mode once you click the Firmware Upgrade button iv If Safe Mode is enabled successfully the Antenna Pointi...

Page 59: ...et the terminal Enter security code for factory reset Default 0000 NOTE By default the security code is 0000 Once you change the Terminal PIN the Factory Reset password is changed to match the Termina...

Page 60: ...SABRE RANGER 5000 User Guide 2017 Addvalue Innovation Pte Ltd All rights reserved 60 13 Appendix A Terminal Block Pin Assignment Figure 72...

Page 61: ...9 RS232 CTS RS485 B Software Configurable RS232 RS485 Factory default to RS232 10 GND GROUND 11 RS232 RX RS485 A Software Configurable RS232 RS485 Factory default to RS232 12 RS232 RTS RS485 Y A Soft...

Page 62: ...ts may not be suitable for your application www Schlemmer com 1 1200232 NW23 Black PA6 corrugated pipe ID23 2 X OD28 9 mm 2 3805013 M25 male straight connector black PA6 c w gasket IP65 3 7211977 Blac...

Page 63: ...ndard IP up to 448 464kbps send receive Symmetric Streaming IP Up to 32 64 128kbps Services Standard IP Streaming IP BGAN SIM Only SMS Interfaces 2 x RJ45 Ethernet Ports RJ45 2 x 12 PIN Terminal Block...

Page 64: ...Water Dust IP66 compliant Electrical DC input range 10 8V to 32V Power max 30W excluding DC output 12V Max 1A Power Consumption Receive 6 W Transmit 20 W typical Standby mode 1 W Low power standby Mo...

Page 65: ...ble efforts have been made to ensure its accuracy Addvalue makes no warranty or representation as to the accuracy completeness or fitness for purpose or use of the information Addvalue shall not be li...

Reviews: