background image

                                                                          

 

   

                                

Thank you for purchasing a high-quality WAAGEN-SCHMITT product. Your new scales 
feature tried-and-tested quality and meet the highest technical standards. 

 

Please read  these  Operating  Instructions  carefully  before  using  the product for  the first 
time,  and  keep  them  in  a  safe  place  so  that  you  can  consult  them  again  if  you  need 
further information. 

 

1. 

Start-up

 

 

Inserting the batteries: 
Open the lid of the battery compartment on the underside of the scales and insert the 
batteries supplied (4 x 1.5V AA). Please ensure the correct polarity of the batteries (+/-). 

 

Safety guidelines: 

 

Ensure that no objects fall onto the scales; otherwise, the scales 
may be damaged. 

 

Use only a damp cloth to clean the scales. Never use solvents or 
abrasive cleaning agents. Do not immerse in water. If the scale's 

plastic  parts  come  into  contact  with  grease,  spices,  vinegar  or 
any  other  strongly  spiced  or coloured  foods,  please  ensure  you 
clean them immediately. Keep citric acid away from the scales. 

 

2. Operation

 

 

Switching on the scales: 

Place  the  scales  on  a  firm,  level  surface.  Press  down  on  the  scales'  surface  for about     
2 seconds with a pressure of 500 g to switch the scales on. The backlighting lights up, 
the  display  shows  initially  "HI",  and  once  stabilized,  will  switch  to  "0 g"  or  "0.0  oz" 
depending on setting. The scales are now ready for use.

 

 

Note: If, after activating the scales, a weight-value is displayed, touch the TARE button 
to set the scales to zero. 

 

Units of weight: 
By  touching  the  g/lb

 

button  you  can  change  the  country-specific  unit  of  weight  (g  =  

gram / oz = ounce). Please make sure that the scales are set to the weight-unit relevant 
to you.  

 

Tare weight function: 

Touching the TARE button will set the scales to "0 g". Place e.g. a bowl on the scales, 
and  touch  the  TARE  button  to  set  the  scales  back  to  "0  g".  You  can  repeat  this 
procedure  as  often  as  you  like  until  you  reach  the  scales' max.  load  capacity  (5 kg)  is 
reached. Once you remove your weighed item(s), the total weight is shown as a minus 
value. 
 

 

Automatic deactivation: 
The backlighting of the scales switches off automatically if no weight change is registered 
for  about  10  seconds.  The  scales  will  switch  off  automatically  if no weight  change  is 
registered for about 1 minute. 

 

3. Error messages 

 

"Lo" 

Battery  is  empty  –  Please  replace  the  batteries  with  the  appropriate 
battery type (4 x 1.5V AA). 

 

" OUE

Γ

" = 

Overload  –  The  5  kg  maximum  load  capacity  has  been  exceeded. 
Remove  the  object  from  the  scales  immediately  to  avoid  damaging  the 
scales' load cell unit. 

 

4. Technical data

 

 

Load capacity x gradation:  Max. 5 kg x 1 g

 

Dimensions: 

200 mm x 210 mm x 17 mm

 

Batteries: 

4 x 1.5V AA (included) 

 

Subject to technical changes as a result of product improvements. 

 

5. Warranty

 

 

WAAGEN-SCHMITT  guarantees  the  free  correction  of  defects  resulting  from  material  or 
manufacturing faults through repair or exchange 3 years from the purchase date. Please 
get  your  warranty  section  filled  out  and  stamped  by  the  retailer  when  you  make  your 

purchase.  In  case  of  warranty,  return  the  scales  to your  retailer  along with  the  warranty 
section indicating the reason for your complaint.

 

 

Note:  Extreme  sources  of  electromagnetic  radiation,  such  as  those  caused  by  the 
operation of radio equipment in the vicinity of the scales, can affect the value displayed. 
Once the interference has been eliminated, the product will once again function normally. 
Note: the unit may need to be reset. 

 

Legal information obligation regarding the disposal of batteries: 
Do not dispose of batteries in domestic waste. As a consumer, you are legally required to 
return  used  batteries.  You  may  return  your  used  batteries  to  public  collection  points  in 
your community or to any retailer that sells batteries of the same type. 

 

Note:

 

The following symbols are used on batteries: 
Li 

Battery contains lithium 

Al 

Battery contains alkaline 

Mn    = 

Battery contains manganese 

 

CR (Li); AA (Al, Mn); AAA (Al, Mn) 

 

 

Summary of Contents for KE 1506

Page 1: ...ng des Herstellers Diese Waage wurde gem den harmonisierten europ ischen Normen hergestellt Es entspricht den Bestimmungen der unten angef hrten EG Richtlinien EMV Richtlinie 2004 108 EG ber die elekt...

Page 2: ...ste und setzen somit die Waage wieder auf 0 g Dieser Vorgang l sst sich bis zum Erreichen der Gesamt kapazit t der Waage 5 kg beliebig oft wiederholen Nach dem Abnehmen des Wiege guts wird das Gesamtg...

Page 3: ...Page 3 1 4 The symbol on the product or its packaging indicates that this product must not be disposed of with regular household waste instead it must be disposed of at a collection point for the rec...

Page 4: ...ou like until you reach the scales max load capacity 5 kg is reached Once you remove your weighed item s the total weight is shown as a minus value Automatic deactivation The backlighting of the scale...

Page 5: ...on los requisitos establecidos por las directivas CE indicadas a continuaci n Directiva CEM 2004 108 CE sobre compatibilidad electromagn tica Directiva RoHS 2011 65 CE en todas sus ediciones Esta decl...

Page 6: ...ad total de la b scula 5 kg Cuando se retire de nuevo el producto pesado el peso total se mostrar como valor negativo Desconexi n autom tica de la b scula Cuando el peso visualizado no cambia durante...

Page 7: ...nis es Conforme aux dispositions des directives europ ennes indiqu es ci dessous Directive CEM 2004 108 CE sur la compatibilit lectromagn tique Directive RoHS 2011 65 CE dans leurs versions respective...

Page 8: ...us peut tre r p t aussi souvent que n cessaire jusqu ce que la capacit totale de la balance 5 kg soit atteinte Apr s avoir enlev le produit peser le poids total est indiqu comme valeur n gative Arr t...

Page 9: ...e disposizioni delle direttive europee elencate qui di seguito Direttiva EMC 2004 108 CE riguardante la compatibilit elettromagnetica Direttiva RoHS 2011 65 CE nelle versioni attuali La presente dichi...

Page 10: ...ncia 5 kg Dopo il prelevamento dell oggetto pesato il peso totale viene visualizzato come valore negativo Spegnimento automatico della bilancia Se il peso visualizzato non varia entro un intervallo di...

Page 11: ...e normen Ze voldoet aan de hieronder opgesomde EG richtlijnen EMC richtlijn 2004 108 EG inzake elektromagnetische compatibiliteit RoHS richtlijn 2011 65 EG In de huidige geldende versies De verklaring...

Page 12: ...tot het bereiken van de max capaciteit van de weegschaal 5 kg zo vaak u wilt herhalen Na het wegnemen van het weeggoed wordt het totale gewicht als negatieve waarde weergegeven Automatisch uitscha kel...

Reviews: