Procedures: 
 
1.  Center punch small indent for hole. 
2.  Drill the required pilot hole. 
3.  Set-up the chassis punch per instructions and 

tighten nut to cut the desired hole size. 

4.  Clean up sharp edges with file. 
 

2.  Mounting the faucet 
 

Disassemble hardware from the threaded nipple, 
except for chrome base plates and rubber washers.  
(Rubber washers may be replaced with bead of 
plumber's putty for neater appearance.) 
 
Feed the threaded nipple through sink or counter 
mounting hole and orient the faucet.  From below 
sink or counter, assemble the white spacer flat 
washer, star washer and hex nut on threaded nipple 
and tighten by hand. After checking faucet 
orientation, tighten with a wrench until secure. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Faucet installation 
 
 

3.  Feed water valve and tubing installation 

 
The saddle tapping valve which is supplied is 
designed for use with 3/8" to 1/2" OD soft copper 
supply tubing (plain or chromed) and rigid metal 
pipe.  Do not use with flexible ribbed supply tubing, 
which is too thin and requires special hardware. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
Self-taping feed water saddle valve installation 

 
Installation procedures using soft copper tubing: 
 
1.  Turn off cold water valve from under sink or 

main water line valve for whole house. 

2.  Before installing saddle tapping valve, make 

sure piercing lance does not protrude beyond 
rubber gasket. 

3.  Assemble saddle valve on copper tubing. 
4.  Turn handle clockwise to pierce soft copper 

tube until valve is firmly seated.  (Valve is 
closed in this position.) 

5.  Turn on water supply to pressure cold water 

line. 

6.  Snug nut/seal with wrench around valve stem. 
7.  Connect tubing to feed water valve using brass 

compression nut, insert and plastic sleeve. 

 
Saddle valve installations with metal pipe: 
 
1.  Turn off cold water supply. 
2.  Drill 3/16" hole at desired location. 
3.  At this point, make sure piercing lance does not 

protrude beyond rubber gasket. 

4.  Assemble saddle on to pipe, aligning with hole. 
5.  Turn saddle valve handle clockwise to close 

valve. 

6. Tighten nut/seal around valve stem with 

wrench. 

7.  Connect tubing to feed water valve using brass 

compression nut, insert and plastic sleeve. 

8.  Turn on cold water supply. 
9.  To open valve, turn handle counterclockwise 

and check for leaks. 

 

4.  Initial tubing connections 
 

For convenience on under counter installations it 
may be advisable to complete under counter hose 
connections at this time. 
 
 

5.   Unit installation

 

 
To mount the drinking water unit, elevate it at least 
2" off the floor, level it and mark the location of 
mounting holes needed.  Drill holes for mounting 
screws and install screws, allowing the mounting 
bracket slots to slip over them. 
 
Note:  If the cabinet sidewalls are not solid, unit 
may sit on the floor with screws to keep it against 
the cabinet in a vertical position. 
 

6.  Final tubing connections 
 

With all components in place, complete final tubing 
connections using these guidelines: 
 

 

Summary of Contents for Residential Drinking Water System

Page 1: ...Installation Instructions AdEdge Residential Drinking Water System OPERATION MANUAL AdEdge Technologies Inc 5152 Belle Wood Court Suite A Buford GA 30518...

Page 2: ...EM LOCATION 2 Faucet 2 Feed water connection 2 Site reparation 2 Description INSTALLATION STEPS 2 1 Faucet installation 2 2 Mounting the faucet 4 3 Feed water valve and tube installation 4 4 Initial t...

Page 3: ...ble space Do not install unit where temperatures fall below freezing otherwise damage will result Connection to an icemaker should also be considered for optimum performance Guidelines for component p...

Page 4: ...g spring loaded porcelain cutter making certain a complete ring has been cut through the porcelain enamel to the metal base 6 Cut away the inner porcelain enamel disc down to the base metal Make certa...

Page 5: ...lve on copper tubing 4 Turn handle clockwise to pierce soft copper tube until valve is firmly seated Valve is closed in this position 5 Turn on water supply to pressure cold water line 6 Snug nut seal...

Page 6: ...es Initial water may be slightly discolored or contain a few small particles of filter media These particles are harmless and non toxic This is normal during filter conditioning and will subside prior...

Page 7: ...710S two filter housings faucet feed water saddle valve tubing fittings and a water meter which will count gallons and automatically shut off the system once 1000 gallons has been filtered This specia...

Reviews: