background image

Via Luigi Barchi 9/B – Reggio Emilia 42124 – Italy 

Phone : +39 0522 345518 – 

www.adelsystem.com 

 

  

DPY351 

Monitor and Control Panel for ADELBus Network devices 

Instruction Manual

 

Thank you for having chosen one of our products for your work.  
We are certain that it will give the utmost satisfaction and be a notable 
help on your job and application. 

Product Description 

The  DPY351  is  a  robust  and  versatile  multifunction  display  that  allows 
monitoring, configuring and managing ADELSystem connected devices 
in an ADELBus network. It is equipped with a high-brightness and wide 
viewing-angle 3.5’’ TFT screen which guarantees an optimum visibility in 
any operating condition. The user interface is clear, intuitive and allows 
configuring  and  managing  the  ADELBus  network  through  its  Ethernet 
interface  by  remotely  monitoring  the  connected  devices,  using  the 
SNMP,  Modbus  TCP  and  MQTTs  protocols.  The  configuration  of  the 
Ethernet connection is very straightforward and can be done by means 
of the embedded webserver or the intuitive user interface. The device IP 
addressing  can  be  static  or  dynamic  using  the  DHCP  protocol.  This 
makes the

 

connection of a DPY351 to a LAN very easy. It is possible to 

connect several devices in chain together, up to 32.  
 

 

 
 
 

Table of Contents 

Product Description .............................................................................. 1

 

1

 

Safety and warning notes .................................................... 2

 

2

 

How to Install ........................................................................ 2

 

2.1

 

Dimensions ............................................................................. 2

 

2.2

 

Panel Mounting....................................................................... 2

 

2.3

 

How to Supply DPY351 .......................................................... 2

 

2.4

 

Device Connection (Fig.2) ...................................................... 2

 

2.4.1

 

Auxiliary temperature sensor (AUX1) ............................... 2

 

2.4.2

 

Ethernet Connection (AUX2) ............................................ 2

 

2.4.3

 

PowerBus Connection (AUX3) ......................................... 2

 

2.4.4

 

USB Connection (AUX4) .................................................. 2

 

2.4.5

 

Auxiliary Input Power (AUX5) ........................................... 2

 

2.4.6

 

Input / Output State Terminal 3,4,7,8 (AUX5) .................. 2

 

2.4.7

 

How to connect the shunt in CBI Size 3 ........................... 2

 

2.4.8

 

Cabel Connections (AUX5) .............................................. 2

 

2.5

 

Power On Configuration ......................................................... 3

 

2.5.1

 

Automatic Power On Display (AUX6) ............................... 3

 

2.6

 

Hardware configurations RS485 and CAN bus ..................... 3

 

2.6.1

 

RS 485 Terminations (AUX6) ........................................... 3

 

2.6.2

 

Can Terminations (AUX6) ................................................ 3

 

2.7

 

Keyboard ................................................................................ 3

 

3

 

ADELBus Connections ........................................................ 3

 

3.1

 

Event based commands ......................................................... 3

 

3.2

 

How to set up an ADELBus network ...................................... 3

 

3.3

 

How to set an ADELBus network with more than one DPY351 

(Modbus View Mode) .......................................................................... 3

 

4

 

Ethernet Configuration ........................................................ 3

 

4.1.1

 

Connect HTTP server for the first time ............................. 3

 

4.1.2

 

Customizing the ethernet interface and services ............. 3

 

4.1.3

 

Saving / resetting the customized ethernet parameters ... 4

 

5

 

Features for Managing ......................................................... 4

 

5.1

 

Monitoring ............................................................................... 4

 

5.1.1

 

Display Configuration”Welcomepage” .............................. 4

 

5.1.2

 

Display Configuration “Network menu” ............................. 4

 

5.2

 

Configuration .......................................................................... 4

 

5.3

 

Daisy Chain ............................................................................ 4

 

5.4

 

Alarms management............................................................... 4

 

5.5

 

History ..................................................................................... 4

 

5.6

 

Event ....................................................................................... 4

 

6

 

Technical Data ...................................................................... 4

 

6.1

 

Input Data ............................................................................... 4

 

6.2

 

User Interface ......................................................................... 4

 

6.2.1

 

Display Screen .................................................................. 4

 

6.2.2

 

Controls ............................................................................. 4

 

6.3

 

Data Connection ..................................................................... 4

 

6.3.1

 

Modbus Communication RS485 ....................................... 4

 

6.3.2

 

CAN Communication ........................................................ 5

 

6.4

 

Ambient Conditions................................................................. 5

 

6.5

 

General Data .......................................................................... 5

 

6.6

 

Accessory ............................................................................... 5

 

6.7

 

Hardware Port ......................................................................... 5

 

6.7.1

 

Digital Input ports “Aux5” .................................................. 5

 

6.7.2

 

Analog Input ports “Aux5” ................................................. 5

 

6.7.3

 

Output port “Aux5” ............................................................ 5

 

6.8

 

Software Port .......................................................................... 5

 

6.8.1

 

Remote Monitoring “Ethernet Connection” ....................... 5

 

6.8.2

 

Web Server ....................................................................... 5

 

6.9

 

Norms and certifications ......................................................... 5

 

6.9.1

 

Immunity and Emission ..................................................... 5

 

6.10

 

Electrical Safety for mounting ................................................. 5

 

6.10.1

 

Environmental Norm Conditions ................................. 5

 

7.1

 

Annex 1: Mounting template: .................................................. 5

 